Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

IAQ (CO2, Temp, RH, And Atm. Pressure) Data Logger with Bluetooth KCC320 Sauermann

Mã sản phẩm: KCC320
Sử dụng cho Model:
Hãng SX: Sauermann
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng
Class 320 data loggers are specifically adapted to the needs of the industry and laboratories. These data loggers stand out with their connected technologies. Two features make your life easier: the smart plug sensors and the mobile application via Bluetooth connectivity.

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

Features


KCC320 IAQ (CO2, Temp, RH, And Atm. Pressure) Data Logger with Bluetooth
Bluetooth communication for smartphones & tablets (Android and IOS)
Record up to 4 parameters simultaneously
Monitoring mode for detailed reporting outside of set points
Large storage capacity of 2,000,000 points
Fast data downloading: 18,000 points/second
Supplied with an anti-theft wall mount with lock
Magnetic back for fast & simple mounting
Large 2-line LCD screen
2 configurable alarm set points per channel
Free, downloadable basic software


Model KCC 320 KPA 320
Units displayed °F, °C, %RH, hPa, ppm °F, °C, %RH, hPa
Resolution 0.1°F, 0.1°C, 1 ppm, 0.1%RH, 1 hPa 0.1°F, 0.1°C, 0.1%RH, 1 hPa
External input Micro-USB female connector Micro-USB female connector
Input for probe N/A N/A
Internal sensor Humidity, temperature, atmospheric pressure, CO2 Humidity, temperature, atmospheric pressure
Type of sensor Capacitive, piezoresistive, NDIR Capacitive, piezoresistive
Measuring range Temp.: -4 to 158°F (-20 to 70°C)
Humidity: 0 to 100%RH
Atm. pressure: 800 to 1100 hPa
CO2: 0 to 5000 ppm
Temp.: -4 to 158°F (-20 to 70°C)
Humidity: 0 to 100%RH
Atm. pressure: 800 to 1100 hPa
Accuracies 1 Temp.: ±0.8°F from 32 to 122°F
(±0.4°C from 0 to 50°C)
±1.5°F below 32°F or above 122°F
(±0.8°C below 0°C or above 50°C)

Humidity 2 : ±2%RH
from 5 to 95% @ 59 to 77°F (15 to 25°C)

Atm. pressure: ±3 hPa

CO2 : ±50 ppm ±3% of the reading
Temp.: ±0.8°F from 32 to 122°F
(±0.4°C from 0 to 50°C)
±1.5°F below 32°F or above 122°F
(±0.8°C below 0°C or above 50°C)

Humidity 2 : ±2%RH
from 5 to 95% @ 59 to 77°F (15 to 25°C)

Atm. pressure: ±3 hPa
Alarm set points 2 alarm set points per channel 2 alarm set points per channel
Frequency of measurements 15 s to 24 h 1 s to 24 h
Operating temperature 32 to 122°F (0 to 50°C) 32 to 122°F (0 to 50°C)
Storage temperature -40 to 185°F (-40 to 85°C) -40 to 185°F (-40 to 85°C)
Battery life 3 years 7 years
Warranty 1 year 1 year
Directives 2011/65EU RoHS II; 2012/19/EU WEEE; FCC part 15; UL 61010


Bình luận