*1 These valuse for a minimum phase difference of 1 μs may vary depending on the output cable length.
*2 The alarm function may not operate when an abnormal offset is generated due to a broken wire, etc
This product might change without a previous notice for the improvement, confirm the function and the performance with the latest specifications.
|
Model
|
MJ100
|
MJ110
|
Power supplyPower supply voltage
|
DC5V(4.5V~6V)
|
DC12V~30V(11V~31V)
|
Power consumption
|
4W
|
3W
|
Output interface
|
Line driver (EIA-422 compliance)
|
NPN open collector(IOL=50mA max.)
|
Output
|
AB quadrature・Z phase・UVW phases・Alarm
|
AB quadrature・Z phase・Alarm
|
Number of divisions
|
1000, 960, 800, 512, 500, 480, 400, 256, 240, 200, 128, 120, 100, 80, 64, 40 and 1/2 of each of these (which does not satisfy the synchronized reference point specifications.)
|
Maximum response speed
|
1000divisions
|
6kHz:when connected to PL25 1800m/min when connected to PL60 720m/min
|
600Hz:when connected to PL25 180m/min when connected to PL60 72m/min*1
|
500divisions
|
15kHz:when connected to PL25 4500m/min when connected to PL60 1800m/min
|
1.5kHz:when connected to PL25 450m/min when connected to PL60 180m/min*1
|
200divisions
|
42kHz:when connected to PL25 12600m/min when connected to PL60 5000m/min
|
4.2kHz:when connected to PL25 1260m/min when connected to PL60 500m/min*1
|
120divisions
|
70kHz:when connected to PL25 21000m/min when connected to PL60 8400m/min
|
7.4kHz:when connected to PL25 2220m/min when connected to PL60 888m/min*1
|
Phase difference
|
100ns
|
1μs
|
Alarm*2
|
Speed alarm (minimum phase difference time or maximum response frequency); Level alarm (0.4 Vp-p or less); Minimum alarm time: approximately 400 ms
|
System startup time
|
Within 0.5 seconds after the power comes on line
|
Compatible head unit
|
PL25or PL60
|
Operating temperature
|
0℃~45℃
|
Storage temperature
|
-20℃~60℃
|
Dimensions
|
138×93×26(mm) ncluding protrusions
|
Mass
|
350 g
|
Accessories
|
Manual・Output connector・connector cap・mounting screws・Ferrite core
|
Option
|
SET-P16-1 (for external reference point) Scale extension cable, external reference point extension cable, Output connector with cable
|