PROGRAMS AND USEFUL FUNCTIONS
HORIZONTAL-For the alignment of horizontal machines train by any position of 9,12,3 or 6’clock, or less 120º rotation method. VERTICAL-For the alignment of vertical and flange-mounted machines by any position of 9,12,3 or 6’clock, or less 120º rotation method.
SOFT FOOT-To check that the machine is properly standing on all feet and remove “soft-foot” if occur.
THERMAL GROWTH-Input of cold coupling target for the thermal alignment compensation, considering difference in thermal growth between machines.
ALIGNMENT SHIM SIMULATOR-Shims simulation function that allows to check the possibility of use of the present shims in case they differ from the results of the calculations.
MY DOCUMENTS-Versatile PC compatible file system (FAT) ► allows to organize data file storage and report print.
FALCON EYE-Quick and easy rough alignment procedure in the presence of a large initial misalignment, while turning machine shaft the laser beams travel outside the detectors. No need to adjust laser beam while taking measurement to ensure smooth measurement.
Specification and Features
Separation distance between measuring transducer units, 5m
Display control operating temperature range, -10..+55 degree C
Measurement accuracy, 1%+0.01
Laser type: Visible red 635-670 nm, <1 mW
Detector type: Positional-sensitive photodiodes, 10х10 mm
Display resolution, 0.01 or 0.001 mm
Measuring resolution, 0.001mm
Electronic inclinometer resolution, 0.1 degree
Power supply: Rechargeable NiMH battery
Built-in application programs and options:
horizontal shaft alignment at any 90º shaft position;
vertical shaft alignment; Setup options;
horizontal shaft alignment with rotation angle less than 120º;
Soft foot;
thermal growth;
selection of shimming simulator to calculate for expected alignment;