The GST-400 should be located on or near a work station. Installation of the GST-400 consists of connecting the GND post on the back of the unit to ground and the AUX post on the back of the unit to the work surface, using the wires provided, and selecting the desired range for the upper limit. The upper limit should be selected based on the ESD sensitivity of the components being handled by the operator. The GST-400 case must be isolated from ground, with only the rubber feet touching the work surface. The work surface should be tested at least once a day. Operators should test their resistance to ground (through a wrist strap or another grounding system) several times a day.