Specification |
CM-3001 |
Vibration input channels |
|
1 ~ 6ch *Select at the time of purchase |
Speed input channels |
|
0 ~ 6ch *Select at the time of purchase |
Vibration value resolution |
|
Acc.P:1.3% of vibration measurement range |
Monitor mode |
【Standard】
【Optional】 |
OverAll vibration
Freq. band, Unbalance vibration |
Signal input |
|
Accelerometer with built-in amplifer (CCLD 2mA/DC24V for sensor) |
Filter |
【HPF】
【LPF】
|
3Hz / 10Hz / 1kHz Cutoff characteristics:-24dB/oct
200Hz / 1kHz / 5kHz / 20kHz Cutoff characteristics:-24dB/oct
Scope of application : OverAll vibration, Freq. band, Timewave form |
Alarm |
|
Upper limit 2 steps : Caution / Warning
Thresholds can be set arbitrarily.
Corresponding relay contact turns ON in case of alarm.
Display unit shows alarm type and status. |
Alarm delay function |
|
0 ~ 99s (In 1 sec. increments) Immediate alarm when set to 0 sec.
An abnormality is detected when the vibration value exceeding the threshold value continues for more than a set period of time.
Prevents false detection due to sudden disturbance vibration. |
Input abnormality detection |
|
Detects sensor disconnection or short circuit and reports an error
*Only when a sensor with built-in amplifier is selected |
Alarm return method |
|
Return by touch panel operation or input from external I/O |
Automatic threshold setting |
|
Automatic threshold setting relative to normal vibration values |
Setting Data Switching |
|
Automatic / Manual / Remotely switchable |
Display |
|
3.5inch color LCD
LED lamp (Display of currently selected setting data number and alarm status) |
Panel interface |
|
Touch panel, Swiches for setting data selection |
Meas. Value Detection Circuit |
|
Digtal processing method |