Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

Online humidity measurement M-Sens 2 SWR Engineering

Mã sản phẩm: M-Sens 2
Sử dụng cho Model:
Hãng SX: SWR Engineering
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng
The M-Sens 2 is used for the continuous measurement of humidity on solids of all kinds.
The M-Sens 2 sensor can ideally be used, for example in container outlets, conveyor belts, conveyor screws, mixers and conveyor dryers.
It is important that the measuring surface of the sensor is always covered with material. The M-Sens 2 is a contact-measuring procedure. The ceramic disc (measuring surface) must always be covered with material.

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

The microwave sensor for continuous humidity measurement
in dry bulk solids


Simple retrofitting for measurement in container outlets, conveyor screws, on conveyor belts, slides etc.
 
Humidity ranges 0 ... 65 % (depending on material)
Measurement accuracy 0.1 %
Online humidity measurement
Independent of the material flow
Temperature-resistant up to 120 °C
ATEX-certified
Recording of surface humidity and capillary humidity


Sensor Housing Stainless steel 1.4571
  Sensor surface Ceramic
  Protection category IP 67 according to EN 60529
  Ex-protection (optional) Zone 20 (dust), zone 0 (gas)
  Material ambient temperature 0 ... + 120 °C
  Working pressure max. 10 bar
  Power consumption 0.6 W
  Weight approx. 1.0 kg
  Response time 0.1 seconds
  Measuring range 0... 65 % residual moisture (depending on material)
  Accuracy 0.1 % absolutely in the calibrated measuring range
  Connecting cable shielded cable 4-wired, 0.25 mm²
    V
Transmitter|Power supply|110/230 V AC (50 Hz) 24 V DC 
|Power consumption|20 W / 24 V 
|Current consumption|max. 1 A at 24 V 
|Protection category|IP 65 according to EN 60529/10.91 
|Operating temperature|- 10... + 45 °C 
|Dimensions |258 x 237 x 174 mm (W x H x D) 
|Weight|approx. 2.5 kg 
|Interface|RS 232, RS 485 
|Cable glands|3x M16 (4.5-10 mm Ø) 
|Cable cross section|0.2 - 2.5 mm² [AWG 24-14] 
|Current output signal|1 x 4 ... 20 mA (0 ... 20 mA), load < 500 Ohm
|Switched output measuring alarm|Relay with two-way contact max. 250 V AC, 1 A 
|Digital inputs|2 inputs for active external control signals 
|Data protection|Flash 
||


Bình luận