Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

Thiết bị đo khí - 709 Combustion Efficiency Analyzer with Differential Manometer - TPI

Mã sản phẩm: 709 Combustion
Sử dụng cho Model:
Hãng SX: TPI
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng

Máy đo khí 

Model : 709 Combustion Efficiency Analyzer with Differential Manometer

Hãng sản xuất : TPI

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

Máy đo khí 

Model : 709 Combustion Efficiency Analyzer with Differential Manometer

Hãng sản xuất : TPI

Combustion Efficiency Analyzer w/ Differential Manometer. The carbon monoxide sensor used in TPI combustion efficiency analyzers feature an on-board filter capable of filtering NO (nitric oxide), NO2 (nitrogen dioxide) and NOX (combination of NO and NO2) to prevent cross sensitivity errors.

Use TPI analyzers to test flue gases in gas and oil fired equipment including high efficiency furnaces and condensing boilers. Measure CO, O2, and stack temperature.

Determine combustion efficiency, CO2, and CO air free. Built-in differential manometer, combustible gas detection, PC communication, data logging, and can measure NO / NOX.

  • All the features of the 708 PLUS high resolution 0.001 in H20 differential manometer for high efficiency and oil equipment
  • Measure CO, and temperature
  • Calculate CO2, efficiency, excess air, and CO air free

Carbon Monoxide (CO)
 Measurement
 Range 0 to 10,000 ppm
 Resolution 1 ppm
 Accuracy +/-5ppm or 5% of reading whichever is greater
 Oxygen (02) Measurement  Range 0 to 25%
 Resolution 0.1%
 Accuracy ±0.3%
 Carbon Dioxide (CO2)  Range 0 to 25%
 Resolution 0.1%
 Calculated Value
 Nitric Oxide Measurement  N/A
 NOX Measurement  N/A
 Temperature Measurement  Range -40 to 1472°F, or -40 to 800°C
 Resolution 1°F or °C
 Accuracy (K-type) ±0.3%, ±2°F or ±1°C
 Draft/Pressure
 Measurement
 Selectable Ranges mBar,kPa, and inH2O
 Ranges -150 mBar to +150 mBar -15 kPa to +15 kPa -60
 inH2O to +60 in H20
 Resolution 0.001 inH2O
 Accuracy ±0/5% fsd
 Gross/Net Efficiency  Range 0 to 100%
 Resolution 0.1%
 Calculated Value
 CO/CO2 Ratio  Range 0 to 0.999
 Resolution 0.001
 Calculated Value
 Operating Temperature  14°F to 122°F (-10°C to 50°C)
 Battery Type  1.5V AA (3)
 Selectable Fuels  Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal,
 Anthracite Coal, Coke, Butane, Wood, Bagasse
 Display Type  Backlit 3 line LCD
 Data Storage  50 Locations
 Data Logging  N/A
 Print Capability  Yes, via optional IR printer (A740)
 PC Communication  N/A
 Date and Time Function  24 Hour Real Time Clock
 Dimensions  200mm x 90mm x 60mm
 Weight  500g
 Conformity  BS7927 (and the draft BS7967)