Máy đo khí
Model : 717 Flue Gas Analyzer
Hãng sản xuất : TPI
TPI Model 717 Flue Gas Analyzer. The TPI 717 Combustion Analyzer is a state of the art, easy to use analyzer designed not only to display and calculate the required readings from a flue but also to cover most of the other desirable parameters associated with appliance installation and maintenance.
Fast purge and the ability to perform fuel selection during start up enable tests to be performed quickly without requiring extra set-up time after initial startup. TPI analyzers also use the last selected fuel as the default setting. This feature prevents the need to perform fuel selection every time the analyzer is turned on.
- Combustion Efficiency Analyzer: Measure O2, CO, and flue temperature. Calculate efficiency, excess air, CO2 & (CO/CO2) Ratio.
- CO Analyzer: Measure carbon monoxide in ambient air.
- Differential Manometer: +/- 150 mBar (0.01 mBar resolution). Great for tightness/let by or burner pressure testing.
- Differential Thermometer: Dual input K-Type thermocouple thermometer measures differential temperatures. Ideal for measuring & recording flow & return temperatures.
- Integrated Magnet for hands-free use; Push on fittings for fast and easy use
Instrument |
Operating Temperature Range |
14°F to +122°F (-10°C to +50°C) |
Battery / Batery Life |
Rechargeable Ni-MH / > 6 Hours |
Charger Input Voltage |
115V or 230V : 50/60 Hz AC |
Fuels |
Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal,
Anthracite Coal, Coke, Butane, Wood, Bagasse |
Pressure Ranges |
mbar, kPa & inH2O |
Display |
Backlit Graphic LCD |
Data Storage |
50 sets of readings, multiple pages |
Time and Date |
24 Hour Real Time Clock |
Dimensions |
200mm x 90mm x 60mm |
Weight |
500g |
Casing |
Rubber Boot as Standard |
Switch Off |
Failsafe |
Exhaust |
Safety Spigot |
Conforms to |
EN50379 |
Flue Temperature Probe |
Construction |
Pistol Grip with Stainless Steel Shaft |
Hose Length |
2500mm |
Insertion Length |
200mm |
'K' Type Thermocouple Accuracy |
+/- 0.3%, +/- 1˚C |
Maximum Temperature |
800°C |
Gases |
Range |
Resolution |
Accuracy |
Oxygen |
0-25% |
0.1% |
+/- 0.3% |
Carbon Monoxide |
0-10,000 ppm |
1 ppm |
<20ppm +/- 3 ppm
>100ppm +/- 5% |
Carbon Dioxide (calculated) |
0-25% |
0.1% |
+/- 0.3% |
Combustion Efficiency |
0-100% |
0.1% |
|
Pressure Measurement |
Selectable Ranges |
mbar, kPa and inH2O |
Range |
- 150 mbar to + 150 mbar |
Resolution |
0.01 mbar & 0.1 mbar |
Accuracy |
+/- 0.5% fsd |
|