Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

Thiết bị đo khí SMAN460 Fieldpiece

Mã sản phẩm: SMAN460
Sử dụng cho Model:
Hãng SX: Fieldpiece
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng
Extra rugged design
Live real-time adjustments with wireless measurements
Micron vacuum gauge with alarms, stopwatch, and rate indicator
Large 3/8" full bore and VAC port
All measurements on screen at one time

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

The SMAN460 wireless four-port digital manifold is the top-of-the-line Fieldpiece manifold.  It has more features and benefits than any other manifold on the market.  With target superheat automatically calculated, simultaneous superheat and subcooling, all 9 measurements displayed on the large, easy-to-read screen, extra large 3/8' full bore and 4th VAC port, and wireless measurements for real-time system diagnosis and charging, the SMAN460 is the manifold HVACR pros trust to do more.


Coupled with the JL2 Job LinkTM Mobile System Transmitter and the SDP2 Dual In-duct Psychrometer, you get all your readings in the Job LinkTM Mobile System App as well as pre- and post-work check lists, in-depth system diagnostics, report emailing, and cloud storage for all work completed.


Plus it has a built in micron vacuum gauge with gives technicians the ability to set high and low alarms, and a stopwatch, as well as view the micron rate of change. 


Units of Measurement:
- Psig, kPa, MPa, bar, inHg, and cmHg
Measures:
- 2 Pressures
- 2 Temperatures
Calculates:
- Superheat
- Subcooling
- Target Superheat
- Vapor Saturation
- Liquid Saturation
Wireless Advantage
- Receive indoor wet bulb and outdoor dry bulb measurements for live target superheat (additional instruments required).
- Send measurements to Fieldpiece wireless system analyzers for diagnostics, data storage, and reporting.
Micron Alarms and Stopwatch
- Set high and low alarms (microns of mercury).
- Activate low alarm when you start pulling down. The stopwatch will start. When your low alarm sounds, the stopwatch will restart.
- Activate high alarm when you isolate the system and the stopwatch resets again. When the system rises to your high alarm, the stopwatch will freeze. 
- Watch rate of change while pulling vacuum.
4 Ports for One Time Hookup
- Connect to high side, low side, vacuum pump, micron gauge, and recovery machine (or refrigerant tank). Then use the valves as needed to recover, evacuate and charge the system.
3/8” Vacuum Port
- The large 3/8” vacuum port and 3/8” full bore speeds up evacuation and charging.

Bình luận