Mass flowmeter consists of a drive magnet vibrating a sensor tube in natural frequency, two U-type tubes, a position detection sensor, and temperature detection. If fluid passes, coriolis force occurs to the vibration and its reverse directions, causing twist. Twist amplitude is in proportion to mass flow rate. That is, if the velocity of flow is faster, twist amplitude is bigger. Mass flowmeter is to detect this amplitude by a position sensor.