Three pairs of sensors for accuracy of ±0.2% of rate
・High accuracy
±0.2% of rate
Using the new algorithm for calculating the flow velocity, it can measure any type of fluid with high accuracy.
・Low maintenance
With no moving parts, FST has long-term stability while requiring only minimal maintenance work.
・Bubble resistant
By using the advanced anti-bubble measurement technology, the interference from air bubbles is greatly eliminated.
・Wide temperature range from -40°C to +150°C
Non conductive fluid including oil, mixed liquid, purified water can be measured.
・Easy-to-operate
with backlit LCD and front panel operation
General specifications
Principle |
Transit time difference method with the advanced ABM (anti-bubble measurement) system |
Pipe diameter (mm) |
⌀50 (⌀80 and ⌀100 versions are coming soon) |
Flow velocity range |
Minimum 0 to 0.3 m/s or -0.3 to 0 m/s
Maximum 0 to 10 m/s or -10 to 0 m/s |
Flow range |
Minimum 0 to 2.11 m3/h
Maximum 0 to 70.6 m3/h |
Power supply |
100–240 V AC (+10% -15%), 50/60 Hz |
Power consumption |
Approx. 20 VA (AC power) |
Arrestor |
provided as standard, on power supply port and analog output port |
Enclosure |
IP66 |
Operating environment |
-40°C to +60°C, RH 90% or less |
Fluid conditions
Fluid |
Liquid (uniform liquid through which ultrasonic wave can propagate) |
Bubble content |
≤ 12 vol% |
Turbidity |
≤ 10,000 mg/L |
Fluid condition |
fully-developed turbulent or laminar flow in a fully-filled pipe |
Fluid temperature |
-40°C to +150℃ |
Pressure |
Up to flange rating |
Kinematic viscosity |
≤ 100 mm2/s |
Detector
Wetted parts material |
Flow cell: stainless steel 316L
Flange: stainless steel 316L
Sensor wetted parts: stainless steel 316L |
Housing |
SCS13 |
Process connections |
Flange (horizontal or vertical mounting) |
Flange rating |
JIS10K/JIS20K
ANSI 150/300
DIN PN16/40 |
|