Electronic volumeter with integrated volume corrector (battery-operated, service life min. 6 years)
Special version for corrosive gas
Electronic, battery-operated counting mechanism (service life min. 6 years)
Torqueless metering system showing total gas flow in volume units (working cubic meter)
High accuracy
Horizontal or vertical gas flow
Standard LF and HF frequency outputs
Calculation of the K coefficient acc. to GERG 88S or AGA 8 gross method 1
Serial RS 485 interface with Modbus protocol
Current output (external power supply unit required)
Explosion protection: II 2 G EEx ib[ia] II C T4/T3
Read-out and parameterization program EC Visit