| Sensitivity | 
            1 µCi/m3 (0.05 DAC) | 
        
        
            | Accuracy | 
            ±3 µCi/m3 from 1 to 100 µCi/m3, ±10% from 100 µCi/m3 to 20,000 µCi/m3 | 
        
        
            | Range | 
            1 µCi/m3 to 20,000 µCi/m3 | 
        
        
            | Detector | 
            4 matched chambers - Two for measuring, two for compensation | 
        
        
            | Measuring chamber effective volume | 
            500 cc (2 measuring chambers of 250 cc each) | 
        
        
            | Flow rate | 
            1.4 L/m | 
        
        
            | Zero stability | 
            ±1 µCi/m3 after unit is powered on for 5 minutes | 
        
        
            | Background cancellation | 
            Less than 10% of the reading change in 10 mR/hr field | 
        
        
            | Radon compensation | 
            Included in the software | 
        
        
            | Ion trap | 
            Removes charge in the air before the measuring chambers | 
        
        
            | Dust filter | 
            Built into the unit | 
        
        
            | Noble gas cancellation | 
            Ports for air inlet/outlet of measuring chambers and compensation chambers are accessible on surface plate so silica gel drier can be placed between the chambers to compensate for presence of noble gas | 
        
        
            | Tritium discrimination | 
            Instrument can discriminate in a field of HTO and elemental H3 using the silica gel drier | 
        
        
            | Purge/Decontamination | 
            All 4 chambers can be heated up by a cartridge heater controlled by the unit | 
        
        
            | Display | 
            Graphic LCD display. Unit displays the values (tritium and Gamma) both in numerical format and graphical trend | 
        
        
            | Communication | 
            Can be configured to RS232 (short distance) or RS485 (long distance) | 
        
        
            | Analog output | 
            0-5 V linear or logarithmic voltage output | 
        
        
            | Power supply | 
            2.5 V - 5 V external power supply, or 3 C-cell battery. Total power consumption is 150 mA | 
        
        
            | Gamma measurement | 
            At same time, the Gamma is measured by the unit. Gamma measuring range is from 0.1 mR/h to 10 R/h | 
        
        
            | Alarm | 
            Tritium, Gamma and Low air flow alarms. Alarm will be shown by Red LED light and sound by audible device | 
        
        
            | Data logging | 
            The tritium and Gamma values are logged every minute with current time and date stamp | 
        
        
            | Size and weight | 
            8"(L) x 5"(H) x 5"(W), 5 lbs | 
        
        
            | Drier | 
            Note that the silica gel drier is not part of the standard equipment . It requires an additional accessory kit |