True continuous monitoring (versus pulsed or intermittent) of wrist strap functionality and operator safety according to accepted industry standards.
Park Delay Feature
Allows operator to disconnect wrist strap cord when normally leaving the workstation without audible (false) alarm sounding.
Dual Status LEDs and Audible Alarm for Operator and Workstation Monitoring
LEDs illuminate (Green) when operator, work surface, and electrical grounds are functioning correctly. visual alarms activate instantly when a failure occurs, alerting user and supervisor of problem, allowing immediate corrective action.
Single Station Continuous Monitor for Operator, ESD Work Surface, and the Operator’s Electrical Ground
Continuously monitors ground integrity of a single operator, ESD workstation and the electrical ground that the monitor is connected to. Eliminates the need for periodic testing and record keeping.
Wave Distortion Technology Provides Real-Time Continuous Monitoring for Operator Path to Ground and Presence of 1 Meg Resistor
Alarm Signal
Use with an external relay (see relay box item 50547) to control access to equipment or other accessories.
Use with Single-Wire Wrist Straps. Includes Desco Wrist Strap 09070
Calibration Unit Available for Accurate Performance and Conformity Testing in the Field. See Desco Item 98220
NIST Calibrated with Certificate