Model
|
CS9933X
|
ACW
|
voltage
|
range
|
0.050kV~5.000kV
|
accuracy
|
±(2%read value+5V)
|
resolution
|
1V
|
Max output power
|
100VA(5.000kV/20mA)
|
Test current
|
20mA
|
Low-current
|
|
Range
|
200uA、2mA、20mA
|
Waveform
|
Sine wave
|
Distortion
|
≤2%( Unloaded or resistance of the load )
|
Crest factor
|
1.3~1.5
|
Waveform mode
|
DDS+ Amplifier
|
Rise time
|
0.3s~999.9s 0= OFF
|
Test time
|
0.3s~999.9s 0= Continuous
|
Descend time
|
0.3s~999.9s 0= OFF
|
Interval time
|
0.0s~999.9s 0= OFF
|
Output mode
|
N mode 、G mode
|
DCW
|
|
range
|
0.050kV~6.000kV
|
accuracy
|
±(2%read value+5V)
|
resolution
|
1V
|
Maximum power
|
60W(6.000kV/10mA)
|
Test current
|
10mA
|
range
|
2uA、20uA、200uA、2mA、10mA
|
Ripple coefficient
|
≤5%(6kV/10mA)
|
Discharge time
|
≤200ms
|
Maximum charge current
|
10mA
|
Voltage rise time
|
0.3s~999.9s 0= OFF
|
Test time
|
0.3s~999.9s 0= Continuous
|
Fall time
|
0.3s~999.9s 0= OFF
|
Interval time
|
0.0s~999.9s 0= OFF
|
Delay alarm time
|
0.3s~999.9s 0= OFF
|
Output mode
|
N mode 、G mode
|
IR
|
Output
voltage
|
range
|
0.050kV~1.000kV
|
accuracy
|
±(2%read value+5V)
|
resolution
|
1V
|
Maximum high-limit
|
9.999GΩ
|
Maximum low-limit
|
9.999GΩ
|
Minimum low-limit
|
1MΩ
|
Rise time
|
0.3~999.9s 0= OFF
|
Test time
|
0.3s~999.9s 0= Continuous
|
Interval time
|
0.0s~999.9s 0= OFF
|
Auto range
|
ON / OFF
|
Discharge time
|
≤200ms
|
GR
|
Output
current
|
range
|
3.0A~30.0A
|
accuracy
|
±(2%read value+0.2A)
|
resolution
|
0.01A
|
Max output power
|
135W(30A/0.15Ω)
|
Max output current
|
30A
|
High-limit of GR
|
|
Waveform
|
Sine wave
|
Distortion
|
|
Crest factor
|
1.3~1.5
|
Waveform mode
|
|
Test time
|
0.3s~999.9s 0= Continuous
|
Interval time
|
0.0s~999.9s 0=OFF
|
Volt
meter
|
range
|
0.050kV~6.000kV
|
Accuracy
|
±(2%read value+5V)
|
Resolution
|
1V
|
Displayed value
|
RMS
|
meter
|
range
|
AC
|
0 ~ 20mA
|
DC
|
0 ~ 10mA
|
resolution
|
AC
|
200uA:0.1uA, 2mA:1uA, 20mA:10uA
|
DC
|
2uA:0.001uA,20uA:0.01uA,200uA:0.1uA,2mA:1uA,
10mA:10uA
|
Accuracy
|
≥2Ma:±(2%+5counts),<2mA:±(3%+5counts)
|
Offset current
|
Current of test leads and accessories can be deducted.
|
Mode
|
GND:RETURN terminal is connected to the case
FLOAT:RETURN terminal is not connected to the case
|
IR ohm meter
|
Range
|
1MΩ~9999MΩ
|
Resolution
|
1MΩ~9.999MΩ:0.001MΩ,10MΩ~99.99MΩ:0.01MΩ,
100MΩ~999.9MΩ:0.1MΩ,1000MΩ~9999MΩ:1MΩ
|
Accuracy
|
0.100kV~0.200kV:1MΩ~999MΩ ±5%, 1000MΩ~3000MΩ ±10%
0.201kV~0.499kV:1MΩ~999MΩ ±5%, 1000MΩ~5000MΩ ±10%
0.500kV~1.000kV:1MΩ~999MΩ ±5%, 1000MΩ~9999MΩ ±10%
|
GR Ampere meter
|
Range
|
3.00A~30.00A
|
Resolution
|
0.01A
|
Accuracy
|
±(2%read value+0.2A)
|
Displayed value
|
RMS
|
GR ohm meter
|
Range
|
0~510mΩ
|
Accuracy
|
current<5.00A:±(3%read value+3mΩ) current≥5.00A:±(2%read value+2mΩ)
|
Resolution
|
0.1mΩ
|
Measure method
|
4-terminal method
|
Timer
|
Range
|
0~999.9s
|
|
0.1s
|
Accuracy
|
±(0.1%+50ms)
|