Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

Thiết bị phân tích khí ZAFE Fuji Electric

Mã sản phẩm: ZAFE
Sử dụng cho Model:
Hãng SX: Fuji Electric
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng
Ideal for H2, Ar, and He measurement
Easy-to-see LCD
RS-232C communication (option)
Compact, panel mount design
Automatic calibration (option)
Interference compensation (option)
Concentration alarm (option)
High/low limit, high-high limit, or low-low limit
Range switching (option) by key on the front panel or by an external contact input.
NEPSI (Exd IIC T6Gb) certified

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

Specifications


Standard specifications Principle Thermal conductivity
Components He, Ar, H2, CH4, CO2
Range H2: 0–3 ‥‥ 100%, 100–90%, 100–80%
He: 0–5 ‥‥ 100%, 100–90%, 100–80%
Ar: 0–10 ‥‥ 100%, 100–90%, 100–80%
CH4: 0–20 ‥‥ 100%, 100–80%
Output signal 4–20 mA DC, 0–1 V DC, or 0–10 mV DC, non-isolated output
Load resistance ≤ 550Ω (at 4–20 mA DC output)
Output resistance 100 kΩ (at 0–1 V DC or 0–10 mV DC)
Display LCD with back light
Display 4-digit
Output hold In both manual and automatic calibrations, output value just before calibration can be held
Power supply & consumption 100–240 V AC, 50/60 Hz, approx. 50 VA
Ambient temperature & humidity -5 to 45°C, RH 90% or less (non condensation)
Mounting Wall mount
Dimensions (H x W x D) 470 × 354 × 211 mm
Weight Approx. 22 kg
Enclosure Dustproof and rainproof (IP65 equivalent)
Gas inlet/outlet Rc 1/2, NPT 1/2, or G 1/2 (as specified)
Ex-proof standard NEPSI (Exd IIC T6Gb)
Performance Repeatability ±1%FS
Drift Zero point: ≤ ±2% FS per week (H2 measurement)
Span point: ≤ ±2% FS per week (H2 measurement)
Response speed (90% response) Standard: ≤ 60 s (at flow rate 0.4 L/min)
High speed: ≤ 10 s (at flow rate 1 L/min)
allowed only for H2 measurement (reference gas N2)
Gas conditions 
Temperature 0–50°C
Gas flow rate Constant at 0.4 ±0.05 L/min
Dust ≤ 100 μg/Nm3 in particle size of 0.3 μm or smaller
Pressure ≤ 10 kPa
Mist, corrosive gas Unallowable
Moisture Below saturation at 2°C
Optional specifications
Relay contact output 5 SPST relay contact outputs
Relay contact capacity: 220 V AC/2A (resistive load)
Isolated with relay between contacts, and between contacts and internal circuit.
Max. 5 functions can be selected among those listed below.
① Zero-side solenoid valve drive output for automatic calibration
② Span-side solenoid valve drive output for automatic calibration
③ Suction pump OFF output in automatic calibration
④ Upper limit (1 point) concentration alarm output
⑤ Lower limit (1 point) concentration alarm output
⑥ Upper/lower limit (1point) concentration alarm output
⑦ Upper limit (1 point) and lower limit (1 point) concentration alarm output (Total 2 points)
⑧ 2-step upper limit (1 point at each step) concentration alarm output (Total 2 points)
⑨ 2-step lower limit (1 point at each step) concentration alarm output (Total 2 points)
⑩ Analyzer error or automatic calibration error alarm output
⑪ Calibrating status output
⑫ Range identification output (for 2 range type only) 
Contact input 3 non-voltage contact inputs ON: 0 V, OFF: 5V DC, current at ON: 5mA Isolated with photo coupler between inputs and internal circuit. Not isolated between contact inputs. The following actions are available: 
① Remote holding of measured value output ② Remote range changeover (only with 2-range analyzer) ③ Remote start of automatic calibration 
Interference gas measured value input 1–5 V DC analog input for H2 analyzer interference correction
Either CO2 or CH4 value measured by an external gas analyzer 
Adjustment at Fuji Electric factory is required. We will check the details of the gas to be measured when receiving an order.
Auto calibration Zero and span calibrations are automatically carried out at the predetermined intervals. Externally installed solenoid valves are driven to flow calibration gas sequentially.
Communication RS-232C (9-pin D-sub output)
Half duplex, asynchronous
MODBUS protocol, communication speed 9600 bps
Contents of communication: Reading/writing of measured concentration values and various set values, and output of device status


Bình luận