| Principle | 
            Non dispersive infrared sensor (single beam system) 
            O2 sensor: built-in magnetic or galvanic sensor, or external zirconia sensor (ZFK7) | 
        
        
            | Measurable components and ranges | 
            NO: 0–10 ppm…100 ppm 
            SO2: 0–10 ppm…100 ppm 
            CO2: 0–5 ppm…50 ppm 
            CO: 0–5 ppm…50 ppm 
            Built-in galvanic O2 sensor: 0–10 vol%…25 vol% 
            Built-in magnetic O2 sensor: 0–5 vol%…100 vol% 
            External zirconia O2 sensor: 0–5 vol%…25 vol% | 
        
        
            | No. of ranges | 
            Up to 2 ranges per component | 
        
        
            | Repeatability | 
            ≤ ±0.5% FS | 
        
        
            | Linearity | 
            ≤ ±1% FS | 
        
        
            | Zero drift | 
            ≤ ±0.5% FS per week | 
        
        
            | Span drift | 
            ≤ ±2% FS per week | 
        
        
            | Response time (for 90%) | 
            ≤ 30 s (Loss time may vary with gas switching timings) | 
        
        
            | Analog output signal | 
            4–20 mA DC or 0–1 V DC | 
        
        
            | Display | 
            Backlit LCD (Japanese, English, or Chinese available)  
            Instantaneous value, O2-corrected instantaneous value, O2 corrected average value, O2 average | 
        
        
            | Range switchover | 
            by key operation, automatic, or by external contact input (option) | 
        
        
            | Contact input (option) | 
            Voltage contact input (12–24 V DC, up to 15 mA) 
            Remote range-switching, auto-calibration remote start, remote hold, average reset | 
        
        
            | Contact output (option) | 
            SPDT relay contact (24 V DC/1 A) 
            Device error, calibration error, range identification, auto-calibration status, solenoid valve drive for auto-calibration, limit alarm, CO peak alarm | 
        
        
            | Atmospheric pressure correction (optional) | 
            Built-in option available | 
        
        
            | Standard functions | 
            Output hold, auto/manual range switching | 
        
        
            | Option | 
            Auto calibration, auto calibration remote start, remote hold of output, range identification contact output, high/low limit alarm, O2 correction, O2-corrected average values, average resetting contact input, CO peak alarm contact output | 
        
        
            | Communication (option) | 
            RS-485 (Modbus) (9-pin D-sub output): half-duplex, start-stop synchronization system | 
        
        
            | Flowmeter | 
            Provided | 
        
        
            | Gas inlet/outlet | 
            Rc 1/4 or NPT 1/4 internal thread | 
        
        
            | Purge gas flow rate | 
            1 L/min (as needed) | 
        
        
            | Reference gas | 
            Required (dry N2 or dry air) | 
        
        
            | Surrounding temperature/humidity | 
            -5°C to +45°C, RH90% or lower (non condensing) | 
        
        
            | Power supply voltage | 
            100–240 V AC, 50/60 Hz | 
        
        
            | Power consumption | 
            Approx. 100 VA | 
        
        
            | Dimensions | 
            133 (H) × 483 (W) × 382 (D) mm | 
        
        
            | Weight | 
            Approx. 11 kg | 
        
        
            | Conformity | 
            CE Marking |