Features
(1) Tests can be performed by selecting resistors of 10 mΩ to 100 mΩ.
(2) By using a short circuit electrode, it is possible to conduct a short circuit test without using a resistor.
(3) When selecting the resistance value, the electromagnetic contactor is thrown in time sharing to suppress inrush current.
(4) Standards UL 1642, JIS C 8712: 2006, 4.3.2, etc. can be tested.
◆ Example of production specification
Resistance value |
10 mΩ to 100 mΩ Selectable
error: ± 10% (at 20 ° C) Switching on energization is not possible |
Rated input |
DC 400 V or 5000 A P |
cooling |
With forced air-cooled filter |
DC power supply for resistance measurement |
Constant current, constant voltage output Output current: 0 to 100 A Output voltage: 0 to 10 V |
Control power supply |
3 Φ 200 V ± 10% 50/60 Hz Input capacity: 5 kVA or less |
Safety device |
Door switch signal output (Close door ON)
Exhaust overheat sensor 2 points (double protection)
Conductor thermostat
Load input voltage monitoring (polarity)
Fan motor monitoring |