Characteristic
Applicable to the Electrical Appliance and Material Safety Law (PSE method) (100 V electrical product exclusive use) Output voltage up to 1200 V, voltage measurement accuracy 1.5 grade, leakage current determination range 1 to 19 mA, timer 99 seconds and
required by the Electrical Appliance and Material Safety Act (PSE method) It corresponds to the dielectric strength test (withstand voltage test).
● Compact, lightweight and simple design The design
is specialized for the dielectric strength test of 100V electric products including household electric appliances, and the ease of testing has been realized.
In addition, it is compact, lightweight and easy to carry.
● High Voltage Output Section Socket
Conformity To make it easy to connect electric products to be tested, the high voltage output side is set as an outlet. In addition, since the high pressure output part
is not touched directly, the safety of the test has also improved.
Basic Specifications
【Test voltage】
Output voltage: AC 0 ~ 1200 V
Voltage output method: Zero cross switch method
Voltage adjustment method: Manual method with
voltage adjustment knob Voltmeter: Analog voltmeter AC 0 to 1500 V (full scale)
Accuracy 1.5 grade
waveform: power supply waveform
frequency: power supply Sync
【Current
detection part】Blocking current setting range: 1 mA to 19 mA
Setting resolution: 1 mA Measurement
accuracy: ± (5% + 0.5 mA) of set value
(at power supply waveform distortion of 5% or less)
[Timer part]
When setting: At the time of setting time after starting, execute the test until issuing FAIL OFF Setting:
Test
until stop input or until
FAIL is output
Setting range: 1 to 99 sec
Setting resolution and Accuracy:
± (1% + 50 msec) of set value 1 sec
Decision Function
determination method: analog comparator scheme
determination content
PASS: below the cut-off current value measuring current is set
if the test has been completed (at timer end)
FAIL: measured current value is greater than the breaking current value set
if
Determination process: Buzzer sound and LED
■ General Specifications ■
Dimensions: about 200 (W) × 148 (H) × 215 (D)
(not including the feet 20 mm projections)
temperature and humidity range: 0 ℃ ~ 40 ℃ 20% ~ 80% RH or less
( condensation never)
storage temperature and humidity range: -10 ℃ ~ 50 ℃ 90% RH or less
(non-condensing)
accuracy guaranteed temperature and humidity range: 23 ℃ ± 5 ℃ 20% ~ 80% RH or less
(non-condensing)
over 10 minutes
Used after warming up : Indoor, altitude 2000 m or less
Power supply voltage: AC 100 V
Power frequency : 50 to 60 Hz
Mass: Approx. 7 kg
Withstand voltage: Power supply - Enclosure AC 1.35 kV 10 mA 1 min
Maximum rated power: 50 VA
Used fuse: 250 VT1AL Accessory: Operating
instructions ....... · · 1
preliminary fuse · · · · · · · · · · · 1
jig for start-up inspection · · · · 1
|