Features
· It is integrated with the power supply transformer with high output voltage of 50 kV.
· Since the cutoff current value can be set arbitrarily, withstand voltage test of the test object can be performed easily.
· Since the test time can be set arbitrarily, output can be turned off automatically at the end of the test.
· Suppresses heat generation by using insulated oiled transformer and heat radiation of product is done by natural air cooling, so
there is no noise due to mounting of FAN motor .
Main
Applications Withstand voltage test of transformers, power supplies, semiconductors, etc. Also, the dielectric breakdown test of the above products.
Electrical specifications
|
Input specification |
1 φ 200 V ± 10% 50/60 Hz |
Output specification |
1φ 0 to 50 kV, 200 mA (max) |
capacity |
10 kVA |
Rating |
Half an hour |
Cutoff current |
10 mA ~ 199 mA 1 mA Step
1 mA ~ 9 mA is not guaranteed 10 mA ~ 99 mA
Error: ± 20%
100 mA ~ 199 mA ± 5% |
timer |
Effective range: 2 seconds to 30 minutes
30 minutes or more is not guaranteed |
Voltage setting |
Manual setting |
General specification
|
Ambient conditions |
Temperature: 0 to 40 ° C
Relative temperature: 85% RH or less |
Size |
W 652 × D 676 × H 1536 protrusion
is not included |
mass |
About 440 kg |
Output Voltmeter |
Digital 50 kV
scale error: 50 kV ± 1.5% |
Output ammeter |
Digital 199.9 mA
scale error: 199.9 mA ± 2.5%
|