- With its real 3-phase test circuit the TTR-3D can address complex ratio measurements of Phase-Shifting/ Regulating or irregular vector group type transformers otherwise impossible to achieve with conventional ratio meters. Zigzag type transformers testing is very easy and will not require the installation of jumpers or the use of relay matrix circuits.
- The single or real 3 phase voltage output up to 275V is very interesting as it contributes to higher magnetization currents and therefore stronger flux for better signal reflection on secondary and/or tertiary windings allowing more accurate results.
The TTR-3D phase displacement measurements enables for simple detection f the transformer vector group.
Thông số kỹ thuật
Ratio Range
|
0.75 to 25000
|
Ratio accuracy
|
0.03% from 0.8 to 1000:1 at 275V
0.05% from 0.8 to 1000:1 with 8V, 40V & 100V
0.1% from 1000 to 5000:1
0.2% from 5000 to 10000:1
0.3% from 10000 to 25000:1
|
Test voltages
|
8V, 40V, 100V, 275V
|
Power input
|
100V to 250V, 45 - 65Hz
|
Phase angle range
|
+/- 180 degrees
|
Phase angle accuracy
|
+/- 0.05 degree
|
Magnetising current range
|
Up to 2A
|
Magnetising current accuracy
|
+/- 1% of range
|
Measuring time
|
5 to 10 seconds
|
Data Storage
|
> 10000 test fi les
|
Display
|
Backlit 6.5” LCD, 640x480, Ultra high brightness,
|
Data displayed
|
- Vector group, phase, tap position, ratio, ratio deviation, phase angle displacement, excitation current, pass-fail results.
- Up to 3 test files can be loaded simultaneously for comparison
- Graphical and tabulated representation of test results
|
Interface
|
USB (USB memory drive), Ethernet (remote control)
|
Tested for
|
EMI, Safety
|
|