Rated Primary Current |
DC/AC15A |
Applicable Current |
±0~51A |
Max. Capable Current |
±51A |
Applicable Frequency |
0~300kHz |
Output Voltage |
625mV F.S (between Ref. and Out.) |
Accuracy |
±1.5% F.S |
Response Time |
Approx. 0.3μs |
Power Supply |
+5V±5%(Unipolar) |
Power Consumption |
Approx. 30mA |
Wiring Method |
+:+5V 0V:COM OUT:Output REF:Ref |
Rated Voltage |
Less than DC/AC500V for low voltage circuit of coated wires |
Withstanding Voltage |
AC4000V/1 minute (between output terminal and CT) |
Insulation Resistance |
More than 100MΩ by 500V insulation tester (between output terminal and CT) |
Operation Temperature |
-40~85℃, less than 75%RH w/o condensation |
Dimension |
16.2×21.7×23mm |
Weight |
Approx. 10g |
Environmental Standard |
Conforming RoHS Directive |