| Rated Primary Current |
DC/AC25A |
| Applicable Current |
±0~85A |
| Max. Capable Current |
±85A |
| Applicable Frequency |
0~300kHz |
| Output Voltage |
625mV F.S (between Ref. and Out.) |
| Accuracy |
±1.5% F.S |
| Response Time |
Approx. 0.3μs |
| Power Supply |
+5V±5%(Unipolar) |
| Power Consumption |
Approx. 35mA |
| Wiring Method |
+:+5V 0V:COM OUT:Output REF:Ref |
| Rated Voltage |
Less than DC/AC500V for low voltage circuit of coated wires |
| Withstanding Voltage |
AC4000V/1 minute (between output terminal and CT) |
| Insulation Resistance |
More than 100MΩ by 500V insulation tester (between output terminal and CT) |
| Operation Temperature |
-40~85℃, less than 75%RH w/o condensation |
| Dimension |
16.2×21.7×23mm |
| Weight |
Approx. 10g |
| Environmental Standard |
Conforming RoHS Directive |