- Detects:
+ Combustible Gases
+ Hydrogen
+ Refrigerants: All CFC’s, HCFC’s & HFC’s
- The 55800 leak detector employs a new metal oxide gas sensor for the detection of chlorofluorocarbon gasses and blends. This tin oxide sensor is characterized by high sensitivity and a fast response, upon detecting the presence of extremely small levels of chlorofluorocarbon gases. Integrated into the design is a powerful microprocessor that automatically selects the best operating conditions for the sensor, to ensure optimum performance. The optimum sensor performance is maintained and monitored throughout the life of the sensor.
- SENSITIVITY:
+ HIGH ≥ 0.05 oz/yr (1.5 g/yr)
+ MEDIUM ≥ 0.25 oz/yr (7 g/yr)
+ LOW ≥ 0.5 oz/yr (14 g/yr)
- PROBE: Intelligent tip design that senses the condition of the environment, to eliminate the potential of false alarms.• Flexible 16” probe for difficult to reach locations
- DISPLAY:
+ Progressive LCD with vertical bars corresponding to the magnitude of the detected leak
+ Visual indication of the selected sensitivity range
- REFRIGERANTS:
+ Detects all refrigerants (CFC’s, HCFC’s, & HFC’s)
+ Unit has been tested and approved to work with R1234yf as well as R32 and R410a
- SENSOR LIFE: 2000 hours
- OPERATING TEMPERATURE RANGE: 0 to 140˚F
- POWER: Two (2) D Batteries
- BATTERY LIFE: 60 hours continuous use
- WEIGHT: 1 lb. 8 oz
- LCD FEATURES:
+ WAIT: This indication flashes whenever the unit is in the wait mode. This could occur whenever the unit is turned on or interference is detected
+ READY: This indication appears when the unit is ready for use
+ INT: This indication appears whenever the microprocessor detects conditions that are not suitable for reliable leak detection. Excessive wind blowing, blocked probe (no air flow), burned out fan, or a missing or defective sensor that needs to be replaced
+ BATTERY SYMBOL: When the battery symbol becomes illuminated this is an indication that the battery is low and needs to be replaced
+ H – M – L: High, Medium and Low sensitivity ranges will be displayed accordingly based on the selection made on the keypad
+ SIGNAL LEVEL BARS: There are 10 vertical signal level bars on the display corresponding to the level of signal detected by the unit
+ ERROR SIGNALS: E1 through E9 indicates diagnostic signals
- KEYPAD FUNCTIONS:
+ ON/OFF: Press the ON/OFF button on the center of the keypad to turn the unit on or off
+ VOLUME/MUTE: Press the VOLUME/MUTE button to control the volume of the unit
+ H M L SENSITIVITY: Press the H M L SENSITIVITY button to select the desired sensitivity level
+ HOLD: Press the HOLD button to freeze the signal bars. Press the HOLD button again to disengage
+ PEAK: Press the PEAK button when multiple leaks are suspected as being present