Bridge power supply |
DC10 V±0.3 V within 30 mA
(Changeable to DC5 V or DC2.5 V) |
Input range |
0.5 mV/V ~ 3 mV/V |
Sensitivity adjustable range |
1 000 times, 2 000 times or 3 000 times
(Changeover with the internal dip switch)
Adjust 1/1 ~ 1/4 against each setting. |
Output |
DC±10 V (Not isolated) |
Output Load Resistance |
2 k-ohm or more |
Zero adjustment range |
±0.25 mV/V *Tare weight cancellation will be adjusted by installing resistance externally. |
Non-linearity |
within 0.02 %F.S. |
Temperature efficient |
Zero point ±1 μV/℃ (Input conversion),
Sensitibity within ±0.01 %F.S/℃ |
Frequency response range |
1 Hz, 10 Hz, 100 Hz, 1 kHz (Changeable by internal DIP switch) |
CALIB |
1 mV/V±0.002 mV/V (Changeable to either 0.5 mV/V±0.001 mV/V or 0.25 mV/V±0.000 5mV/V if specified at the order.) |
Operating temp./humidity range |
Temperature -10 ℃ ~ 50 ℃,
Humidity 85%RH or less (Non condensing) |
Power supply |
Power supply voltage AC100 V (AC90 V ~ 115 V), 50/60 Hz,
Power consumption Approx. 5 VA (at AC100 V) |
Outline dimensions
(W x H x D) |
CSA-507C 44 mm x 90 mm x 110 mm
CSA-507C-99 44 mm x 90 mm x 230 mm
(Excludes protruding parts) |
Weight |
CSA-507C Approx. 700 g