Features


Pressure transmitter for the measuring of relative and absolute pressures of gases, vapors and liquids in applications for food and pharmaceutical industry
Stainless steel case in hygienic design, degree of protection IP 65/67
Accuracy 0.1 %
High-resolution graphic display with Intuitive 4-button operation and backlight
Comprehensive parameterising functions

Yêu Cầu Giá Tốt

Thông tin sản phẩm

Hygienic design
Hygienic design The surface quality of the wetted parts made of stainless steel is of major importance. The hygienic type device (Code: HY) guarantees the following surface roughness values:
Diaphragm foil: Ra ≤ 0.4 µm
Laser welds: Ra ≤ 0.8 µm
Turned parts: Ra ≤ 0.8 µm
Further versions of hygienic design upon request.
Measuring system
Sensor: Piezoresistive measuring element
System filling: Synthetic oil, free of silicon FD1, FDA listed, class USDA-H1
Accuracy
Reference cond.: per DIN EN 60770-1
TU = const. (15…25) °C 
φ = const. (45...75) % r.F.
pU = const. (860...1060) mbar
UB = 24 V DC (± 3 V DC)
RB = 50 Ω, HART: 250 Ω
Ground connected
MBA = 0 bar
Calibration position: Process connection bottom: vertical
Process connection back: horizontal
Deviation of characteristic: Refer to the adjusted measuring span (Limit point method per DIN 16086)
  Nominal range 1-40 bar, 1-16 bar abs.:
Turndown 5:1 0.1 %
Turndown > 5:1 0.02 % x TD
  Nominal range 0.25 bar:
Turndown 5:1 0.15 %
Turndown > 5:1 0.03 % x TD
Long-term drift: Refer to nominal range
≤ 0.1 %/year
Operational availability: < 12 s
Response time t90 at current output: for 20 Hz measuring rate: typically 120 ms
for 100 Hz measuring rate: typically 50 ms
Temperature influence, case: Refer to nominal range
  Ambient temperature -20…80 C:
Nominal range 1-16 bar, 0.1 %/10K, max. 0.3 %
Nominal range 0.25 bar, 0.15 %/10K, max. 0.4 %
  Ambient temperature -40…-20 C:
Typical 0.2 %/10K
Temperature-influence process-connection: Depending on design
  See data sheet for detailed information
Active compensation of process temperatures (ATC-Technology, see General Technical Advices TA_041)