Constructional design / case
Housing material: |
stainless steel, mat.-no. 1.4404 (316L), coated |
Diaphragm material: |
titanium |
Degree of protection: |
IP 68, immersible |
Dlectrical connection: |
stainless steel connector, degree of protection IP 68 |
Cable connection: |
pluggable, slit cable 5 strand, see accessories, observe mounting instructions |
Weights: |
probe: approx. 0.7 kg |
Weights: |
+ supply lines depending on length/m: approx 0.1 kg |
Measuring system: |
sensor: piezoresistive measuring bridge, protected by an internal high-grade steel diaphragm |
|
system filling: silicon free, synthetic oil |
Temperature ranges
Ambient temperature: |
-20...+85 °C |
Storage temperature: |
-25...+85 °C |
Note safety values as per examination certificate!
Supply
Function range: |
12...30 V DC |
Output
Pressure measurement: |
Signal: 4...20 mA, 2-wire circuitry
Current range: 3,8...20,8 mA
Current limitation: 22 mA |
|
Alarm state: < 3.6 mA standard, option: > 21 mA
Response time: 160 ms
Damping: 0...120 seconds, standard: 0.0 sec
Burden: R ≤ UB - 12 V /20 mA (kOhm) |
Temperature measurment: |
Output signal: Pt 100, 2-wire circuitry
Application range: -20...+85 °C
Response time T90: approx. 10 min. |
R ≥ 250 Ω via communication with LEVELcom
|