Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

Đồng hồ đo nhiệt độ FP2300 Labom

Mã sản phẩm: FP2300
Sử dụng cho Model:
Hãng SX: Labom
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng
Features

Case and wetted parts of stainless steel
Different connections can be supplied
Accuracy class 1 or 2 as per DIN 16196, depending on range
Micro adjusting pointer for indication correction
Switch functions (electrical contact device) per DIN 16196: slow acting contact; magnetic snap contact; inductive contact devices

Yêu Cầu Giá Tốt

Thông tin sản phẩm

Constructional design / case
Case high quality bayonet ring case NS 100
material: st. steel mat.-no. 1.4301 (304)
Degree of protection (EN 60529) IP 66
Measuring element helix from thermostatic bimetal per DIN 1715 with good adjusting power and fast acting, thermally aged, base and connection piece laser welded
Temperature detecting element stainless steel mat. no. 1.4571 (316Ti). Diameter 6 and 8 mm. Can be supplied in standard lengths, see order details; other
sizes upon request.
Process connection rigid temperature detecting element, vertical resp. axial protruding at rear. Different connections available, see order details.
Pointer shaft stainless steel mat.-no. 1.4571 (316Ti), with multiple bearings
Scale pure aluminium, white with black inscription
Pointer pure aluminium, black with micro adjusting device for zero-point correction
Window instrument glass, alternatively macrolon with contact lock
Case seal sealing ring: Perbunan
Nominal ranges per EN 13190 see order details. Special ranges upon request.
Accuracy see table in data sheet T3-025
Ambient temperature per EN 13190 ambient temperatures that deviate from EN
are to be specified
Storage and transport temperature per EN 13190 max. -20...+60 °C
  For measuring devices with inductive contact type SJ2-S1N (NS 100, double contact): For safe operation refer to TA_044!
Electrical connection connection plug with cable gland M 20 x 1.5 and removable test cover, mat. Macrolon
Switch function Touch contacts or inductive contact see order code. Further technical details see operating instructions BA_066 and TA_039.
Weight DN 100: approx. 0.6 kg
Instructions for use The loading capacity of the temperature detecting element depends on the following parameters:
1. measured medium
2. measured medium pressure
3. measured medium temperature
4. flow velocity
5. immerison length
6. material
A technical test is necessary where required.