Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

Đồng hồ đo nhiệt độ FU2460 Labom

Mã sản phẩm: FU2460
Sử dụng cho Model:
Hãng SX: Labom
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng
Features

Case, measuring system and clip-on bulb of stainless steel
Simple mounting without thermowell
Accuracy class 1 or 2 as per DIN 16196, depending on range
Micro adjusting pointer for indication correction
Design: bulb fixed welded; indicating unit positioning by rotating the bulb; with capillary (indicating unit independent of measuring point)

Yêu Cầu Giá Tốt

Thông tin sản phẩm

Constructional design / case
Case high quality bayonet ring case NS 100/160, material: st. steel mat.-no. 1.4301 (304)
Degree of protection (EN 60529) IP 66
Measuring element bourdon tube dead zone free with inert gas filling
Capillary stainless steel material no. 1.4571 (316Ti) in different lengths, with buckling protection, coated with protective tube upon request
Clip-on temperature detecting element stainless steel material no. 1.4404 (316L), to fit pipe resp. circular form.
Suited for fast installation on pipe diameter approx. 25...150 mm
Case filling liquid filling Labofin
Process connection rigid clip-on temperature detecting element, radially protruding at bottom, or centrically at rear for horizontal resp. vertical piping; alternatively with capillary
Movement stainless steel with compensation
Scale pure aluminium, white with black inscription.
Option: with marking
Pointer pure aluminium, black with micro adjusting device for zero-point correction
Window non splintering laminated glass. Option: non splintering plastic (Macrolon) with contact lock
Case seal sealing ring: Perbunan
filling plug: Desmopan
Nominal ranges per EN 13190, however max. up to 250 °C
Accuracy class data per DIN 16196 (depending on range) for all temperature detecting elements with diameter d5 and standard immersion length l1 see data sheet T3-030
Ambient temperature per EN 13190 ambient temperatures that deviate from EN
are to be specified
  For measuring devices with inductive contact type SJ2-S1N (NS 100, double contact):For safe operation refer to TA_044!
Storage and transport temperature per EN 13190, max. -20...+60 °C
Electrical connection connection plug with cable gland M 20 x 1.5 and removable test cover, mat. Macrolon
Switch function Touch contacts or inductive contact devices see order code. Further technical details see operating instructions BA_066 and TA_039.
Mounting stand-alone mounting with wall bracket ; alternatively with flange for surface mounting or for flush mounting with DIN mounting flange
Weights DN 100, without filling: approx. 1.3 kg
DN 100, with filling: approx. 2.1 kg
DN 160, without filling: approx. 2.1 kg
DN 160, with filling: approx. 4.4 kg

Bình luận