Type
|
Portable Digital Circuit Breaker Analyzer
|
Physical specifications
|
18K"W x 14"H x 7"D (47.0 cm x 35.7cm x 17.6 cm). 20 lbs (9.1 kg)
|
Input power
|
100-240Vac, 3A, 50/60Hz
|
Dry-contact inputs
|
3 dry-contact channels; each channel detects main contact and insertion resistor contact
|
Timing windows
|
1 second, 10 seconds, or 20 seconds
|
Timing resolutions
|
±50 micro-seconds @ 1 sec. duration, ±500 micro-seconds @ 10 sec. duration, ±1.0 milli-seconds @ 20 sec. duration
|
Timing accuracy
|
0.05% of reading ±0.1 milli-seconds @ 1 second duration
|
Dry-contact detection range
|
Closed: Less than 20 Ohm. Opened: greater than 5000 ohm
|
Resistor detection range
|
50 - 5,000 ohms
|
Trigger input voltage
|
Open/close: 30 - 300 V, DC or peak AC
|
Voltage sensing input range
|
V1: analog input; 0 - 255 V DC or peak AC; sensitivity ±1 V
V2: voltage presence/absence detector input; 30 - 300 V DC or peak AC
|
Breaker operations
|
Initiate Open, Close, Open-Close, Close-Open, Open-Close-Open
|
Breaker initiate capacity
|
30A, 250 Vac/dc max
|
Initiate current reading range
|
One, non-contact, Hall-effect sensor, 0 - 20 amp range, dc to 5 Khz AC
|
Digital travel transducer inputs
|
1 digital travel transducer channel; linear range: 0.0 - 60.0 in (±0.005 in). Rotary range: 0 - 360 degrees (±0.006 degrees)
|
Contact travel point difference
|
Measures “slow-close” contact-point distances; results can be printed
|
CT current sensor
|
One, non-contact, 0-100A
|
Display
|
Back-lit LCD screen (128 x 240 pixels); viewable in bright sunlight and low light
|
Printer
|
Built-in 4½” wide thermal printer that can print both graphic contact travel waveforms and tabulated test results
|
Internal test record storage
|
Store up to 200 test records and 100 test plans
|
Computer interfaces
|
One USB port, optional Bluetooth wireless interface
|
Pc software
|
Windows® based Breaker Analysis software included with purchase price
|
Cables
|
Furnished with full set of test leads (including 20-foot contact leads and 30-foot contact lead extensions)
|
Options
|
Transportation case (available for the DigiAMR and travel transducers)
|
Safety
|
Designed to meet UL/IEC 61010 and CAN/CSA C22.2 No. 1010.1-92 standards
|
Environment
|
Operating: -10°C to +50°C (+15°F to +122°F); Storage: -30°C to +70°C (-22°F to +158°F)
|
Humidity
|
90% RH @ 40°C (104°F) non-condensing
|
Altitude
|
2,000 m (6,562 ft) to full safety specifications
|
Warranty
|
One year on parts and labor
|