Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

FlatPak Surge Eliminator SA82 SurgeX

Mã sản phẩm: SA82
Sử dụng cho Model:
Hãng SX: SurgeX
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng
The SurgeX SA82 FlatPak is the ultimate protection innovation for projectors, flat panels, and digital displays. The SA82's premium protection and design can easily mount to the back of equipment and integrate with wall/ceiling mounting systems. If you're looking for a compact solution that installs out-of-sight, then the FlatPak is the perfect solution.


Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

Features

SA82 FlatPak Surge Eliminator, 8A / 120V, 2 Outlets, Brackets Included
Protects wall/ceiling equipment from power disturbances and catastrophic damage
Provides 100% Fail-safe, non-sacrificial protection
Eliminates surge energy up to 6,000 Volts/3,000 Amps
Ultra compact < 5 lbs design can easily be integrated with wall/ceiling mounting systems
Features SurgeX Series Mode® surge elimination technology, Impedance Tolerant® EMI/RFI Filtering, and Over Voltage Shutdown (with Auto Reset)
Improves audio and video performance
Axess Ready model offers Remote IP control capabilities
Includes detachable IEC power cord and mounting brackets
A-1-1 Certified


Model: SA82 Specifications
Load Rating 8 amps @ 120 volts
Power Requirement (no load) 10 watts
UL 1449-2 Adjunct Classification Test Results 1000 surges, 6000 volts, 3000 amps, C1 pulse, measured suppressed voltage 290 volts, no failures
Federal Guidelines Grade A, Class 1, Mode 1 (CID A-A-55818) A
EMI/RFI Filter, Normal Mode (50-ohm load) 40 dB @ 100 kHz; 50 dB @ 300 kHz; 50 dB @ 3 MHz; 50 dB @ 30 MHz
EMI/RFI Filter, Common Mode (50-ohm load) 18 dB @ 300 kHz; 30 dB @ 1 MHz; 50 dB @ 5 MHz; 50 dB @ 20 MHz
Maximum Applied Surge Pulse Joule Rating Unlimited, due to current limiting (8 x 20 µs)*
Maximum Applied Surge Pulse Voltage 6000 Volts*
Maximum Applied Surge Pulse Current Unlimited, due to current limiting*
Endurance IEEE C62.41-1991 Category B3 (C1)
Pulses 1 kv>500,000; 3 kv>10,000; 6 kv>1000
Overvoltage Shutdown 145 Volts (resume at 135 volts)
Dimensions 1.75" H x 5.31" W x 9.06" D
Weight 3.4 lbs
Temperature Range 5º to 35º C
Humidity Range 5% to 95% R.H., non-condensing
Agency Listings ETL and cETL certified to (UL 1449;
CSA C22.2 No.8-M1986, R2000)