Parameter |
Range |
Accuracy |
Resolution |
Flue Gas Measurements |
O2 |
0-25 % |
± 0.2 % Vol abs |
0.1% Vol |
CO(H2 compensated) |
0-10000 ppm |
± 10 ppm or ± 5 % of reading up to 4000 ppm
± 10 % of reading above 4000 ppm |
1 ppm |
NO(NOx)1
(optional) |
0-5000 ppm |
± 5 ppm or ± 5 % of reading up to 1000 ppm
± 10 % of reading above 1000 ppm |
1 ppm |
SO2
(optional) |
0-5000 ppm |
± 10 ppm or ± 5 % of reading up to 1000 ppm
± 10 % of reading above 1000 ppm |
1 ppm |
Efficiencies( net, gross, condensing)1 |
0 to 120 % |
|
0.1 % |
Air Ratio1 |
1 to 9.99 |
|
0.01 |
CO/CO2 Ratio1 |
0-9999 |
|
0.0001 |
Excess Air1 |
0 to 99.9% |
|
0.1% |
Heat Losses1 |
0 to 99.9 % |
|
0.1 % |
CO2%1 |
0 to CO2% max |
± 0.3% Vol |
0.1% |
Temperature and Pressure measurements |
Gas Temperature |
-50 to 1200°C |
± 2°C |
0.1 °C |
Air Temperature |
-50 to 100°C |
± 1°C |
0.1 °C |
Draught |
± 50 mbar |
±0.02 mbar |
0.01 mbar |
Differential Pressure |
± 300 mbar |
±0.02 mbar |
0.01 mbar |
Fine draught
(Optional) |
± 50 mbar |
±0.01 mbar |
0.001 mbar |
Pre-Programmed fuels |
Nat Gas, Oil Heavy, Oil Light, Propane, Butane
Wood@0%,Wood@10%,Wood@20%, Wood@30%, Wood@40%, Wood@50%, Pellets
Kerosene, Coal, Diesel, Petrol, Coke, Anthracite
4 user define fuels |
Memory, communications and data storage |
Data storage |
16000 data, 4000 sites |
Storage medium |
Internal memory and SD card (2 GB) with data export to SD card in CSV file |
Data export |
Trough USB or SD card in CSV format |
Communications |
MicroUSB, SD Card, IRDA and Bluettooth® |
General |
|
|
|
Display |
6 lines colour graphic display 3.5 ” TFT |
Power |
Standard Rechargeable, Ni-HM batteries, USB charging AC 100-240 VAC, 47-63 Hz – Wall charger and cable included |
Battery Life |
10 hours |
Weight |
750 grams |
Dimension(W x Lx H |
110x225x52 mm |
IP Protection |
IP 40 |
Operating Temperature |
5 to 45 °C |
Storage Temperature |
-20 to 50 °C |
Warranty |
full 2 years manufacturing warranty on instruments and cells |
5 years warranty |
5 years extended warranty when annual serviced by EIUK |
Approval |
Conform to BS 7967 and BS EN 50379-2 |
Standard Flue Gas sampling Probe |
360x 8 mm flue gas probe ( COAXIAL) with integrated thermocouple for temperature measurement and dual hose for continuous draught measurment |
Notes |
1 calculated value |