Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

Máy đo chiều dày lớp sơn, mạ DS-110 Densoku

Mã sản phẩm: DS-110
Sử dụng cho Model:
Hãng SX: Densoku
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng
High accuracy by the crystal oscillator 
can also be measured on the curved surface, spherical pair in a short measurement time

And measurement value display is easy to read in a digital 
start measuring at the same time and put the switch, the measurement time is also within one second 
by-crystal oscillation method, high stability (± 1%) high-precision 
non-destructive but because the total inspection is possible 
, direct reading unnecessary terms because formula

Yêu Cầu Giá Tốt

Thông tin sản phẩm

Features of the eddy current type film thickness meter DS-110

Easy-to-read digital

Measured value display is easy to read in digital.

It can be immediately measured

It can be measured at the same time and put the switch. Measurement time is also within one second.

High stability (± 1%) high accuracy

By a crystal oscillation method, high stability (± 1%) high precision.

Possible total inspection

Because it is non-destructive and can total inspection.

Without the need for conversion

Direct reading does not need to be translated at the formula.

Corresponding to various measurement

Coatings on metal, plating, painting, can be measured such as a resin (for example, oxide film on aluminum, plating such as zinc on iron, paint).

Remote switch

You can read the data by remote switch.

1000 data to be stored

1000 data in a single inspection lines can be saved.

Also measured the metal coating on the non-metallic

You can measure the metal coating on the non-metal (plating on the example plastic).

Standard in four types, can be up to 70 types of film thickness measurement

By switching the switch, you can film thickness measurement of up to four. In addition, by replacing the inspection line by the manufacturer, you can more than 70 types of film thickness measurement.

Curved, spherical body, it can also be measured in the interior of the pipe

Curved surface, can also be measured in a spherical body. You can also measure the pipe such as the inner surface (more than φ12.7mm).

Judgment possible of the material difference

You can determine the material difference.

Print-out function

You can print out the measurement data and statistical processing value.

Measurement principle

Measurement principle When the probe was passed a high-frequency current (the probe coil) is brought closer to the metal, eddy current is generated in the metal surface layer portion. This eddy current, high-frequency magnetic field strength, frequency, received conductivity of the metal, the thickness, the influence by the shape, etc., vary the penetration depth and the size. 
And eddy currents, because it flows so as to cancel a high-frequency magnetic field of the probe, the high-frequency resistance value of the probe will change. To amplify the amount of change in this high-frequency resistance, carried out the curve correction, it will be displayed in a digital value.Because of this, you can read a number of the film thickness value directly. Curve correction is performed in the calculation by the microcomputer. In this for high-precision, high stability.

Specification of the eddy current type film thickness meter DS-110

Power supply AC100V ~ 240V in the AC adapter use
weight 3.4kg
Size 330 (W) × 180 (D) × 90 (H) mm

(Note) The specifications are subject to change without notice.

Probe specification of the eddy current type film thickness meter DS-110

1. effect range of the probe 
during the ultra-fine probe use
Fai5mm 
Fai3mm
2. The length of a code of probe 900mm
Curved surface on the possible measured by 3. guide of type
4. type of probe MP type ... flat uneven for a curved surface (standard) 
MPG type ... flat uneven for a curved surface (Guided) 
SM type ... flat uneven for a curved surface (ultra-fine) 
RP type ... concave surface, for pipe interior surface 
SR type ... small diameter pipe interior surface for 
the above-mentioned probe There are each a, B, C, 4 kinds of D by the film thickness to be measured.
5. probe guide # 180: plane measurement 
# 120: φ25 ~ 60mm convex curved surface measurement for 
# 90: φ30mm convex curved surface measurement of the following