Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

Resonance Test System For Generator GPXZ-L Huatian

Mã sản phẩm: GPXZ-L
Sử dụng cho Model: GPXZ-L, GPXZ-L giá rẻ, báo giá GPXZ-L, giá bán GPXZ-L, GPXZ-L Huatian, Resonance Test System For Generator GPXZ-L, Resonance Test System For Generator GPXZ-L Huatian
Hãng SX: Huatian
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng
Resonance Test System For Generator
Model: GPXZ-L
Hãng: Huatian

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

A- Need smaller power capacity. The power of the serial resonant system generate high voltage and high current by resonant reactor and measured capacitance, in the whole system, power source only provides the power consumption part of the system, so the required power is only 1/Q of the measured capacity.
B- Lighter and smaller volume. Without the heavy power voltage regulating device and test transformer, and excited power is only 1/Q of the measured capacity. The weight and volume are only 1/10-1/30 of the common devices.
C- Improve the output voltage waveform. Resonant power source is resonant filter circuit, which can improve the output voltage waveform distortion, get better sin wave, and effectively prevent D- Prevent the high current to burn out the fault point, for the serial resonant; the circuit will be dissonant as soon as the insulation weakness of the measured device was broken down, the loop current fast decrease to the 1/Q of the normal measured current. But for the parallel resonant or test transformer to do voltage withstand test, the breakdown current , these two compare, short circuit current and breakdown current different in hundreds times. So the serial resonant system can easily find out the insulation weakness, and do not worry about the heavy short circuit current burn out the fault point.
E- Without any recovery over-voltage. When the measured equipment was broken down, it lost the resonant conditions, high voltage immediately disappear, electric arc immediately burn out, and it is a long process to recover the voltage, easily to power off before it get to the flashover voltage another time, it is a long process, without any recovery over-voltage.

- Because the resonant system is reactive power full compensated, the power of the equipment and power is only less than 1/10 of measured equipment; with smaller volume and lighter compared with the equipment in same capacity. The device with large output capacity and small power capacity, low cost, easy to operate and safe.
- Serial resonant system actually is current filter circuit, make the current which through it be fundamental current, the output voltage distortion (THD) is very small, and better than all the AC voltage withstand equipment. 
- The short circuit current after flashover or breakdown is only less than 1/10 (1/Q) of the measured current, can effectively prevent the damage to fault point after breakdown.
- Auto blowout the arc after flashover, it is a long and stable process to recover the serial resonant voltage, safe.



>>> Giá bán HL Series