Frequency range |
|
0.8 GHz to 3.0 GHz, instantaneously;
2.5 GHz to 6.0 GHz, instantaneously |
Nominal power classes |
0.8 GHz to 3.0 GHz |
30 W (44.8 dBm),
60 W (47.8 dBm),
110 W (50.4 dBm),
200 W (53.0 dBm) |
|
2.5 GHz to 6.0 GHz |
15 W (41.8 dBm),
30 W (44.8 dBm),
60 W (47.8 dBm),
100 W (50.0 dBm) |
Nominal output load |
|
50 Ω |
Gain flatness |
|
±3.0 dB (or better, see data sheet) |
Gain adjustment range |
|
> 15 dB |
Spurious |
|
–80 dBc (nom.), max. –70 dBc |
Modulation capability |
|
AM, FM, φM, PM |
Nominal input impedance |
|
50 Ω |
Input level for nominal output power |
|
–3.4 dBm |
Nominal output impedance |
|
50 Ω |
Output mismatch protection |
|
100 % |
RF sample and detected sample signals |
RF sample signal coupling factor |
RF forward and reflected sample ports, optional |
approx. 46 dB (see test report for details) |
Detected sample signal level |
detected forward and reflected sample ports, optional |
0.8 V to 2.6 V DC |
RF and sample connectors |
RF input port |
either front panel |
N female |
|
or rear panel |
N female |
RF output port |
either front panel |
N female |
|
or rear panel |
N female |
RF sample ports |
forward output power, optional |
N female |
|
reflected output power, optional |
N female |
Detected sample ports |
forward output power, optional |
N female |
|
reflected output power, optional |
N female |
Graphical user interface |
Local graphical display |
|
200 × 48 pixel, monochrome |
Web GUI |
via Ethernet |
RJ-45, 10/100 Mbit/s, autonegotiation, half/full duplex |
Remote control |
Ethernet |
|
RJ-45, 10/100 Mbit/s, autonegotiation, half/full duplex |
General data |
Operating voltage range |
|
100 V to 240 V AC ± 10 %, single phase, 50 Hz to 60 Hz ± 6 % |
Power consumption |
depending on power class |
max. 2.0 kVA |
Air cooling |
|
forced air, built-in fans, air entry at front, air exit at rear |
Dimensions |
W × H × D, incl. fans, handles and feet |
430 mm × 196 mm × 580 mm
(16.93 in × 7.72 in × 22.83 in) |
|
for rackmounting |
19" 1/1, 4 HU |
Environmental conditions |
Temperature loading |
operating temperature range |
0 °C to +40 °C |
|
storage temperature range |
–20 °C to +70 °C |
Damp heat |
|
max. +40 °C at 95 % rel. humidity, without condensation |
Altitude |
operating altitude |
up to 2000 m |
|
storage altitude |
up to 4600 m |
Protection |
Input overdrive |
without damage |
max. +15 dBm |
Load VSWR |
|
infinite |
Interlock |
|
1 device interlock, 1 configurable interlock |
Input protection against bias voltage |
optional |
DC block level ≤ 50 V DC |
Transient voltage compatibility |
|
category II, in line with IEC 60364-4-443 |
Short-circuit breaking capacity |
|
automatic all-pole 20 A circuit breaker |
Thermal overload |
|
shutdown at +50 °C ambient temperature |