The EM4058 earth tester is a digital, microprocessor controlled instrument that allows to measure the earth resistance and ground resistivity (using Wenner´s method), as well as to detect parasitic voltages present in the ground. This instrument is suitable to measure earth systems in power substations, industries, distribution networks, etc., according to IEC 61557-5.

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

• Earth resistance measurement

• Ground resistivity (Wenner's method)
• High spurious voltage rejection
• Spurious voltage measurement
• 0.01 Ω resolution
• Up to 20 kΩ resistance range
• Measure with multiples frequencies
  (270 Hz, 570 Hz, 870 Hz, 1170 Hz, 1470 Hz)
• Built-in memory
• USB interface


Operation frequency 
270 Hz (resistance or resistivity measurement) 
570 Hz, 870 Hz, 1170 Hz or 1470 Hz (resistance measurement)
Max. variation: ± 1 Hz (both cases).

Voltmeter 
In the voltmeter function, the equipment operates as a CA conventional voltmeter, making it possible to measure voltages generated by parasitic currents. 

Measurement ranges 
Resistance: 0-20 Ω; 0-200 Ω; 0-2000 Ω y 0-20 kΩ (auto ranging)
Resistivity: 0 - 50 kΩm (autoranging).
Voltage: 0 - 60 V~. 

Accuracy
Resistance and Resistivity measurements:
R ≤ 2 kΩ:± (2% of the measured value ± 2 digits). 
R > 2 kΩ:± (5% of the measured value ± 2 digits). 
Voltage measurement: ± (3% of the measured value ± 2 digits). 

Reading resolution 
0.01 Ω in the resistance measurement.
0.01 Ωm in the resistivity measurement.
0.1 V in the voltage measurement. 

Output current 
The short-circuit current is limited to less than 20.0 mA R.M.S. (according the IEC 61557-5 - 4.5). 

Imunity to spurious voltage interference 
During the R measurement, it allows for the presence of spurious voltage up to 7 V~, with a error < 10%.

Earth resistance of auxiliary rods
In the R measurement it allows Raux up to 50 kΩ with error < 30%. 

Battery status checking 
The battery charge status is verified under normal using conditions.