Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

Thiết bi đo trở kháng vòng lặp_ SONEL _ MZC-305

Mã sản phẩm: MZC-305
Sử dụng cho Model:
Hãng SX: SONEL
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng

Thiết bi đo trở kháng vòng lặp_ SONEL _ MZC-305

Hãng sản suất: SONEL –Ba Lan

Model: MZC-305

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

Thiết bi đo trở kháng vòng lặp_ SONEL _ MZC-305

Hãng sản suất: SONEL –Ba Lan

Model: MZC-305

Thông số kỹ thuật:  

Giao tiếp :usb

Nguồn: pin alkaline hoặc NiMH rechargeable batteries, size AA (4 pcs)

Kích thước: 260x190x60mm

Khối lượng:2,2kg

Measurement of short circuit loop impedance (ZL-PE, ZL-N, ZL-L)

Measuring range according to IEC61557: 0,13…1999? for 1,2m test leads; 0,25…1999? for UNI-SCHUKO adapter

Range

Resolution

Accuracy

0,00...19,99Ω

0,01Ω

±(5% m.v. + 3 digits)

20,0...199,9Ω

0,1Ω

±(4% m.v.. + 3 digits)

200...1999Ω

 

• rated operating voltage UnL-N/ UnL-L: 110/190V, 115/200V, 127/220V, 220/380V, 230/400V, 240/415V, 290/500V, 400/690V,
• operating voltage range: 100…440V (for ZL-PE and ZL-N) and 100…750V (for ZL-L)
• high current measurement (up to 30A),
• operating frequency range: 45…65Hz,
• control of correctness of PE terminal connection by means of a contact electrode (applicable to ZL-PE),
• measurement is also possible when L and N circuits are swapped,
• measurement of resistance and reactance components,
• short circuit current calculation.

Measurement of short circuit loop impedance ZL-PE RCD (without RCD tripping)

Measuring range according to IEC61557: 0,43...1999? for 1,2m test leads; 0,50...1999? for UNI-SCHUKO adapter

Range

Resolution

Accuracy

0,00...19,99Ω

0,01Ω

±(6% m.v. + 10 digits)

20,0...199,9Ω

0,1Ω

±(6% m.v. + 5 digits)

200...1999Ω

 

• operating voltage range: 100 ... 440V,
• rated operating voltage Un: 110V, 115V, 127V, 220V, 230V, 240V, 390V, 400V,
• control of correctness of PE terminal connection by means of a contact electrode,
• measurement is also possible when L and N circuits are swapped,
• measurement of resistance and reactance components,
• short circuit current calculation.

Voltage measurement
 

 

Range

Resolution

Accuracy

0,0V...249,9V

0,1V

±(2% m.v. + 4 digits)

250V...750V

1V

±(2% m.v. + 2 digits)

 

• measurement available for all settings of short-circuit loop (ZL-PE, ZL-PE RCD and ZL-N,L-L),
• frequency range 45…65Hz,
• overvoltage alarm.

Bình luận