| Probe |
Connectors |
2 off 12 Way Lemo 2b (Absolute, Bridge and Reflection) and Lemo 00 (for single element absolute probes) |
| |
Rotary |
Probe 1 only. 600 - 3000 rpm - ETher Mercury Drive (ARD002), Hocking 33A100/40A100, Rohmann MR3, SR1 and SR2 Drive (special adapter needed) |
| |
Conductivity |
Probe 1 only. Option becomes active with use of AeroCheck+ conductivity probe and cable |
| Frequency |
Dual Frequency |
10Hz to 12.8MHz |
| Gain |
Overall |
-18 to 104dB |
| |
Main Gain |
-18 to 82dB, 01, 1 and 6dB steps |
| |
Input |
0dB or 12dB |
| |
Drive |
0dB, 6dB and 10dB (0dB reference 1mW into 50 ohm) |
| |
Max X/Y Ratio |
-18dB to 82dB independent |
| Phase |
Range |
0.0 - 359.9°, 0.1° steps |
| Filters |
Normal High Pass |
DC to 2kHz or Low Pass Filter, whichever is the lower in 1Hz steps. Plus variable adaptive balance drift compensation 0.01 - 0.5Hz (6 steps) |
| |
Normal Low Pass |
1Hz to 2kHz or a quarter of the lowest test frequency whichever is lower in 1Hz steps. |
| Balance |
Manual |
14 internal balance loads; 2.2µH, 5.0µH, 6.0µH, 6.5µH, 7.0µH, 7.5µH, 8.2µH, 12µH, 15µH, 18µH, 22µH, 30µH, 47µH, 82µH |
| |
Automatic |
Optimized balance load selection |
| Mix Channel |
Frequency |
Full frequency range available on both channels |
| |
Probe Mode |
Simultaneous reflection / bridge and absolute including simultaneous two probe Differential and Absolute |
| |
Mix Gain |
X/Y -18 to 18dB |
| |
Mix Phase |
0.0 - 359.9°, 0.1° steps |
| Alarm Gates |
Number |
2 Independent Alarm Gates may be configured on Pane 1, Pane 2 or Both Panes |
| |
Box |
Fully configurable, Freeze, Tone or Visual |
|
Sector |
Fully configurable, Freeze, Tone or Visual |
| Display |
Type |
5.7" (145mm), 18 bit color, daylight readable |
| |
Viewable Area |
4.5" x 3.4" (115.2 x 86.4 mm) |
| |
Resolution |
640 x 480 pixels |
| |
Color Schemes |
User configurable Dark, Bright and Black & White |
| |
Configuration Screen |
Full Screen, Single, Dual Spot or Dual Pane with variable size and location and function e.g. XY, Timebase, Waterfall and Meter |
| |
Display Modes |
Spot, Timebase (0.1-20 seconds x 1-200 sweeps and up to 55 seconds), Waterfall and Meter with peak hold and % readout. |
| |
Graticules |
None, Grid (4 sizes: 5, 10, 15 and 20% FSH), Polar (4 sizes: 5, 10, 15 and 20% FSH) |
| |
Offset |
Spot Position: Y=-50 to 50, X=-65 to 65% |
| |
Spot Readout |
Display in X, Y or R,θ |
| |
Summary |
Display of all settings in Legacy Format |
| Removable Data Storage |
Setup Storage |
micro SD up to 32GB, holding over 10,000 settings |
|
StoredScreen Shots |
micro SD up to 32GB, holding over 10,000 screen shots |
| |
Recorded Data |
micro SD up to 32GB, holding over 500 2.5 minute long data recordings |
| |
Guides |
micro SD up to 32GB, holding 10,000 slides |
| Advanced Features |
Data Logging |
Real time recording of signal data and replay on instrument and desktop PC up to 164 seconds |
| |
Guides |
Create and display a slide show containing instructions, tutorials and procedures using Microsoft PowerPoint. |
| |
Attachments |
Screen shots and data recordings are saved in a folder with the name of the settings |
| |
Loop |
Capture a live repetitive signal and then optimize the instrument settings (Phase, Gain, Filters) to simplify optimizing the parameters. |
| |
Trace |
Allows a calibration reference signal to be stored on the screen and then compared with the live signal. |
| |
Auto Phase |
Allows phase angle to be automatically set to a pre-set angle |
| Inputs/Outputs |
PC Connectivity |
USB (Full PC remote control plus Real Time data) and RS-232 May be set off, 9600,19200, 38400, 57600, 115200, 230400, 460800, 921600 baud. |
| |
Analogue |
2 outputs 2 Volts swing |
| |
Digital Volt Free Alarm |
On Lemo 12 Way Open collector transistor (36v dc at 10mA max). |
| |
VGA |
Full 15 way VGA output (EC screens only) |
| |
I/O |
Two configurable |
| |
Alarm Out |
2 off Opto Isolated 2mA 50v max |
| |
External Alarm Inhibit |
2 TTL Inputs |
| Languages |
|
English, French, Spanish, Italian, Portuguese, Russian, Japanese, Chinese, Turkish, Czech |
| Verification |
|
The system includes on delivery a 2 year validity Verification Level 2 detailed functional check and calibration as per ISO 15548-1:2013. |
| Power On Self Test |
|
The system performs a self test on start up of external RAM, SD, RAM, accelerator, Micro SD card, LCD screen buffer |
| Power |
External |
100-240VAC, 50-60Hz, 30 Watts |
| Physical |
Weight |
7.25 lbs. / 3.3 kg. |
| |
Dimensions |
9.7" x 6.0" x 9.9" / 246 x 152 x 250 mm |
|
Operating Temperature |
-4°F to 140°F / -20°C to 60°C |
| |
Storage Temperature |
Storage for up to 12 months -4°F to 95°F / -20°C to 35°C Nominal 68°F / 20°C |
| |
IP Rating |
IP 54 (front panel only) |