Specifications
3,000 amp FWDC / HWDC or 2,500 amp AC multidirectional output; current capability at contacts
Multidirectional power supply-two outputs (Contacts, Flux-Flow coils)
Duty cycle 0.5 seconds on, 10 seconds off (5% with maximum of 2 seconds)
Off time between magnetizing shots increases for shot time set above 0.5 seconds to maintain 5% duty cycle
41 inch (104 cm) headstock/tailstock capacity
Two Independently variable current controls
Recommended 20 Gallon (75 Liter) Tank Fluid Capacity
Available Voltages: 230, 380, 415, 460, 575, 50 or 60 hertz, 3 phase power
Minimum 80 PSI with 5 SCFM capability
89” (226cm) x 41” (104 cm) Foot Print, allow 24”(61 cm) per side for ventilation
Optional Features
Rapid Reversing FWDC or decaying AC Demagnetization
16 in Coil (40 cm) in lieu of the Flux Flow Coils
Dual Palm Button in lieu of Footswitch
Automatic Bath
Engage/Disengage switch
Adjustable Stroke Length, up to 22 inches
Automatic Mag Shot when Bath Returns
Automatic Bath Shut Off, no flow when bath in retracted position
Articulating Spray Nozzles