Technical Data
|
Contact discharge
|
200V – 30,000V (±5%)
|
Air discharge
|
200V – 30,000V (±5%)
|
Voltage step
|
100V
|
Hold time
|
> 5s
|
Polarity
|
Positive, negative
|
RC module
|
LCD display
|
Temperature and humidity
|
Built-in temperature and humidity meter with functions of record and protection
|
Repetition frequency
|
Single /0.1/0.2/0.5/1/2/5/10/20Hz
|
Trigger mode
|
Manual/automatic
|
Pulse
|
1-9999
|
Contact discharge
|
150pF/330 ohm
|
Summary procedure
|
Test according to different standard levels
|
Rise time
|
0.8ns +/- 25%
|
Quick start test program
|
Simple and easy to reset data online
|
Evaluate procedure
|
Contact discharge test at 20Hz,evaluate the test points of DUT
|
Standard Test Procedure
|
accord with EN/IEC61000-4-2
|
General data
|
Weight
|
Approx 10.6kg
|
Temperature
|
15℃-35℃(operation condition)
|
Humidity
|
30%-60%(operation condition)
|
Air pressure
|
86kPa-106kPa
|
Working power supply
|
100V-240V(±10%); 50/60Hz(default AC 220V 50Hz for China Mainland)
|