Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

Thiết bị phân tích dầu bôi trơn C155OILKIT Uei

Mã sản phẩm: C155OILKIT
Sử dụng cho Model:
Hãng SX: UEi
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng
The newly redesigned Eagle 2X Combustion System Analyzer eliminates the number one hassle for combustion contractors; the annual replacement and calibration of the O2 sensor. By replacing the electro chemical O2 sensor with the EOS Technology™ CO2 sensor, the EAGLE 2X now takes direct CO2 measurements and calculates the O2 level.

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

Measures CO2 (EOS Technology)
CO (Long Life Sensor)
Inlet Temp/Flue Temp
Hi-Res Differential Manometer (select 0.01”/0.001”wc)
NO (EAGLE 3X: installed, EAGLE 2X: available as upgrade)
Calculates O2
Net Temp
Efficiency
Excess Air
Differential Temp (T1-T2)
Differential Pressure (P1-P2)
PreProgrammed Fuels Natural Gas
Propane
Heavy Oil
Light Oil
Bio Fuel
Wood
Eagle X Model C155 C157
Temperature Measurement
Flue Temp Range 20~2400°F (-29~1315°C)
Inlet Temperature (probe - T2) 20~2400°F (-29~1315°C)
Inlet Temperature (ambient) 32~112°F (0~50°C)
Net Temperature (ΔT)** 20~2400°F (-29~1315°C)
Resolution 0.1°C/F
Flue (T1, Inlet T2 & ΔT) Accuracy ±(0.3% rdg +3.6°F(2°C))
Inlet Temperature Accuracy ±(0.3% rdg +1.8°F(1°C))
Gas Measurement
Oxygen 0~21%**
O2 resolution / accuracy 0.1% / ±0.3%
Carbon Monoxide (CO) 0~2000 ppm (4000 max 15 min)*
CO resolution / accuracy 1 ppm / ±10 ppm<100ppm,
±5% rdg>100ppm
Carbon Dioxide (CO2) 0~20%*
CO2 resolution / accuracy 0.1% / ±2%
Efficiency** 0~99.9%**
Efficiency resolution/accuracy 0.1% / ±3%
Excess Air** 0~250%**
Excess Air resolution/accuracy 0.1% / ±3%
CO/CO2 ratio** 0~0.999
CO/CO2 resolution/accuracy 0.001 / ± 5% rdg
Nitric Oxide (NO1)*** - 0~100 ppm
NO1 resolution/accuracy*** - ±2 ppm<30ppm
±5ppm<100 ppm
Pressure (Differential)
Range ±0.08” wc (±0.2mBar)
±0.4” wc (±1mBar)
±32” wc (±80mBar)
Accuracy 2±0.002” wc (±0.005mBar)
±0.01” wc (±0.03mBar)
±3% rdg
Pressure Resolution
Resolution 0.001” wc < 9.999” wc
0.01” wc >10.00” wc
0.001mBar<24.999mBar
0.01mBar > 25 mBar
* Measured at STP (standard temperature and pressure) 0.01” wc >10.00” wc
** Calculated value
*** NO1 sensor installed on C157. Available as an upgrade for C155.

† Gas Zero (Fresh Air Zero) - Is a reset procedure to maintain accurate readings from the EOS sensor. This procedure compensates for any change in ambient conditions that may impact the readings