Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

Transformers Testing TTRT 03 Amperis

Mã sản phẩm: TTRT 03
Sử dụng cho Model:
Hãng SX: Amperis
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng
Transformers Testing
Model: TTRT 03
Hãng: Amperis

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

The TTRT-03 can perform a specific test for each transformer type (such as single phase, delta to Y, Y to delta, delta to delta, or Y to Y) without the need to switch test hookupcables. Also, the unit’s automatic transformer phase detection feature can detect different transformer vector diagrams. The TTRT-03 can automatically detect and test 67 transformer types defined by ANSI, CEI/IEC and Australian standards. To prevent an accidental wrong test-lead hook-up (e.g., when the operator reverses H and X leads), the TTRT-03 outputs a low-level test voltage to verify the hook-up condition before applying the full test voltage to the transformer. In addition to measuring a transformer’s turns-ratio, the TTRT-03 can also measure a transformer’s excitation current (in milli-amperes) and its winding phase angle. Three test voltages (8 Vac, 40 Vac, 100 Vac) allow the TTRT-03 to test CT’s and PT’s, as well as power transformers. The TTRT-03 can also calculate the turns-ratio percentage error if the transformer’s nameplate voltages are provided. The baseline turns-ratio is calculated using the nameplate voltages, and the test results are compared to the baseline turns-ratio. The percentage error is then calculated from the difference between the baseline and test turns-ratios.


Thông số kỹ thuật


Type

Portable, automatic, three-phase transformer turns-ratio meter

Physical specifications

17”W x 7”H x 13” D (43.2 cm x 17.8 cm x 33.0 cm); Weight: 14 lbs (6.4 kg)

Input power

3 amps, 100 - 120 Vac or 200 - 240 Vac (selectable), 50/60 Hz

Measurement method

ANSI/IEEE C57.12.90

Ratio measuring range

0.8 - 15,000 (5-digit resolution)

Turns ratio accuracy

0.8 - 1999: ±0.1%, 2,000 - 3,999: ±0.25%, 4,000 - 15,000: ±1% @ 8 Vac
0.8 - 1999: ±0.1%, 2,000 - 3,999: ±0.20%, 4,000 - 15,000: ±1% @ 40 Vac
0.8 - 1999: ±0.1%, 2,000 - 3,999: ±0.15%, 4,000 - 15,000: ±1% @ 100 Vac

Test voltages

8 Vac @ 1 amp, 40 Vac @ 0.6 amp, 100 Vac @ 0.1 amp

Excitation current reading range

0 - 2 Amperes; Accuracy: ±1mA, ±2% of reading (±1 digit)

Phase angle measure

0 - 360 degrees; Accuracy: ±0.2 degrees ( ±1 digit)

Display

Back-lit LCD screen (20 Characters by 4 Lines); Viewable in bright sunlight and low-light levels

Printer

Built-in 4.5-inch wide thermal printer

Computer interface

One RS-232C port

Pc software

Windows®-based Transformer Turns-Ratio Analyzer application is included

Internal test record storage

Stores 200 complete transformer test records. Each test record includes nameplate voltage, winding turns-ratios, excitation current, and winding phase angle

Internal test planstorage

Stores up to 128 transformer test plans

Safety

UL Certified (UL 61010A-1), CAN/CSA Certified (C22.2 No. 1010.1-92)

Environment

Operating: -10°C to +50°C (+15°F to +122°F); Storage: -30°C to +70°C (-22°F to +158°F)

Humidity

90% RH @ 40°C (104°F) non-condensing

Altitude

2,000 m (6,562 ft) to full safety specifications

Cables

One 15-foot single-phase cable set, one 15-foot 3-phase cable set, one 25-foot extension cable set, one rs-232c cable, cable carrying bag

Optional accessories

Transportation case, transformer load tap-changer remote control device

Warranty

1 year on parts and labor



Bình luận