Measured medium |
Alcohols, milk beverage, seasoning, pure water, chemical or other media that will not corrode SUS316L. |
Pressure type |
Positive, compound, and negative pressures can be measured. |
Pressure range |
Can be specified within the range of 50 kPa to 3 MPa (Calibration:25kPa~3MPa) of rated capacity.
Specify more than 50% of rated capacity as the calibration range. |
Output type |
Specify among 4 to 20 mA (4-wire), 1 to 5 V, 0 to 5 V, and 1 setting output. |
Specification 1 (Sensor assembly)
Sensor Connection |
ISO Ferrule, VARIVENT®, ISO Cap nut, Screw mount, Other special orders |
Rated Capacity(R.C.) |
50, 100, 200, 300, 500, 1000kPa, 3MPa |
Material |
Sensor: SUS316L |
Finish(Sensor Part) |
Electro-Chemical Buffing |
Safe Overload Rating |
400%R.C. (Rated capacity 3MPa: 150%R.C.) |
Destruction Point |
1000%R.C. (Rated capacity 3MPa: 300%R.C.) |
Specification 2 (Amplifier + Sensor assembly)
Non Linearity |
±0.5%R.C. |
Hysteresis |
±0.5%R.C. |
Compensated Temperature Range (Wetted part) |
Standard -5~80°C/High temperature: -5~150°C |
Safe Temperature Range (Wetted part) |
Standard/High temperature: -5~150°C |
Temperature Effect on Zero Balance |
±0.5%R.C./10°C (Rating: 300, 500, 1000kPa, 3MPa) |
±0.7%R.C./10°C (Rating: 50, 100, 200kPa) |
Temperature Effect on Load |
±0.5%R.C./10°C (Rating: 300, 500, 1000kPa, 3MPa) |
±0.7%R.C./10°C (Rating: 50, 100, 200kPa) |
Digit |
1999 3 ½ digit |
Ambient Temperature and Humidity |
Temperature:0~50°C(No freezing), Humidity:0~90%RH(No condensation) |
Material |
Aluminum die-casting(Case material)
Acrylic(Front)
SUS304(Radiating fin) |
IP Rating |
Equivalent to IP65 |
Weight |
Standard: Approx. 860g
High temperature: Approx. 950g |
Accessories |
Operation manual (1 copy)(Specify English or Japanese.)
Test report (1 copy), 1 of O-ring(Screw mount type only)
1 of hexagon nut(Cap nut only) (*1) |
|