■Dedicated to fillers - From chemical cleaning, steam sterilization up to beverage filling.
■Safe and reliable construction with break-proof diaphragm
■Safe and reliable construction with no sealed liquid.
| Measured medium |
Beer, beverage or other media that will not corrode SUS630. |
| Pressure type |
Positive pressure can be measured. |
| Pressure range |
Calibration:0~343kPa |
| Output type |
4~20mA(2 wire system) |
Specification 1 (Sensor assembly)
| Rated Capacity(R.C.) |
500kPa |
| Safe Overload Rating |
400%R.C. |
| Non Linearity |
±0.8%R.C. |
| Hysteresis |
±0.5%R.C. |
| Compensated Temperature Range |
-5~150°C |
| Safe Temperature Range |
-5~150°C |
| Temperature Effect on Zero Balance |
±0.7%R.C./10°C |
| Temperature Effect on Load |
±0.7%R.C./10°C |
| Material |
SUS630 (Pressure port) |
| IP Rating |
Equivalent to IP65 |
| Weight |
Approx. 450g (Sensor + Cable only) |
| Accessories |
Operation manual (1 copy)(Specify English or Japanese.)
Test report (1 copy), Dedicated O-ring |
Specification 2 (Amplifier)
| Analog output |
4~20mA(2 wire system) (Safe load resistance:500Ωmax.) |
| Ambient Temperature and Humidity |
Temperature:0~70°C(No freezing) Humidity:0~90%RH(No condensation) |
| Power |
DC24V±10% |
| Material |
SUS304(Case material) |
| Option |
Amplifier case fixation metal fittings |