Rated Capacity(R.C.) |
Gauge pressure specification VESX: 50, 100, 200, 500kPa (Voltage output type) |
Gauge pressure specification VESZ: 50, 100, 200, 500kPa (Currente output type) |
Output Signal |
VESX: 1~5V (Voltage output type)
VESZ: 4~20mA (Currente output type) |
Response |
5msec. or less |
Safe Load Resistance |
VESX: 1kΩ or more (Voltage output type) |
VESZ: 11.5V:150Ω max. 24V:500Ω max.(Currente output type) |
Non Linearity |
VESX: ±0.25%R.C. or less (Voltage output type) |
VESZ: ±0.5%R.C. or less (Currente output type) |
Hysteresis |
±0.2%R.C. or less |
Compensated Temperature Range
(Temperature of medium to be measured) |
-10~80°C(No condensation or freezing) |
Safe Temperature Range
(Temperature of medium to be measured) |
-20~100°C(No condensation or freezing) |
Temperature Effect on Zero Balance |
±0.5%R.C./10°C |
Temperature Effect on Load |
±0.5%R.C./10°C |
Safe Overload Rating |
300%R.C. |
Ultimate Overload Rating |
400%R.C. |
Insulation Resistance |
10MΩ or more(DC50V) |
Pressure Port Material |
SUS316L (Diaphragm assembly: Hastelloy C22) |
Connection Screw |
Selectable: R1/4 and G1/4 |
Fastening Torque;Recommended |
9.8N・m(G1/4) |
Fastening Torque;Maximum |
19.6N・m |
Power |
VESX: DC12V or DC24V(10~32V) [12mA or less](Voltage output type)
VESZ: DC12V or DC24V [10~26.5V](Currente output type) |
Weight |
Approx. 150g(Cable not included) |
Cable |
0.5SQ Oilproof shielded cable 2m(Standard) |
Accessories |
Operation manual (1 copy)(Specify English or Japanese.)
Test report (1 copy) P-18 4D(×1) (G screw only) |