Non Linearity |
±0.8%R.C. (100MPa: ±1%R.C.) |
Hysteresis |
±0.8%R.C. (100MPa: ±1%R.C.) |
Compensated Temperature Range
(Temperature of medium to be measured) |
-30~70°C(No condensation or freezing) |
Safe Temperature Range
(Temperature of medium to be measured) |
-40~100°C(No condensation or freezing) |
Temperature Effect on Zero Balance |
±0.2%R.C./10°C(100MPa:±1%R.C./10°C) |
Temperature Effect on Load |
±1%R.C./10°C |
Safe Overload Rating |
150%R.C. |
Ultimate Overload Rating |
200%R.C. |
Insulation Resistance |
100MΩ or more (DC50V) |
Pressure Port Material |
SUS630 or 15-5PH (Precipitation hardening stainless steels) (*1) |
Connection Screw |
Selectable: R3/8 and G3/8
(100MPa: G1/2 only) |
Fastening Torque;Recommended |
1~5MPa: 20N・m
10~50MPa: 40N・m, 100MPa: 80N・m |
Fastening Torque;Maximum |
1~5MPa: 30N・m
10~50MPa: 60N・m, 100MPa: 120N・m |
Power |
Selectable: 4DC24V(±10%), 5DC12V(±10%)
*Only 24V DC available when analog output is A5. |
Cable |
4- or 2-core shielded (oilproof) cable
2m(Standard) φ6mm |
Weight |
Approx. 200g(Cable not included) |
Accessories |
Operation manual (1 copy)(Specify English or Japanese.)
Test report (1 copy)
Copper packing(×1)(G screw only) |