■Measures minute and the low pressures (5 to 350 kPa) with high accuracy.(Non Linearity: ±0.5%R.C.)
■Abundant analog output available.
[4~20mA(2 wire system, 4 wire system), 1~5V, 0~5V, 0~10V]
■For the cable connection to the sensor, "pigtail", "standard connector", "waterproof connector" and "terminal box" are available.
Measured medium |
Dedicated to inert gases (noncorrosive gases) such as air, nitrogen, argon, etc. |
Pressure type |
Positive, compound and negative pressures can be measured.
Contact VALCOM for the measurement of absolute pressure. |
Measured Range |
Can be specified within the range of 5 kPa to 350 kPa of rated capacity (Calibration: 2.5~350kPa).
Specify more than 50% of rated capacity as the calibration range. |
Output type |
Specify among 4 to 20 mA (2-wire, 4-wire), 1 to 5 V, 0 to 5 V, and 0 to 10 V. |
Specification
Non Linearity |
±0.5%R.C. |
Hysteresis |
±0.5%R.C. |
Compensated Temperature Range
(Temperature of medium to be measured) |
0~70°C(No condensation or freezing) |
Safe Temperature Range
(Temperature of medium to be measured) |
-20~85°C(No condensation or freezing) |
Temperature Effect on Zero Balance |
±0.5%R.C./10°C |
Temperature Effect on Load |
±0.5%R.C./10°C |
Safe Overload Rating |
200%R.C. |
Ultimate Overload Rating |
300%R.C. |
Insulation Resistance |
50MΩ or more (DC50V) |
Pressure Port Material |
Aluminum 2017(Pressure port: Semiconductor) |
Connection Screw |
Selectable: R3/8 and G3/8 |
Fastening Torque;Recommended |
20N・m |
Fastening Torque;Maximum |
30N・m |
Power |
4DC24V(±10%), 5DC12V(±10%)
*Only 24V DC available when analog output is A5. |
Cable |
4- or 2-core shielded (oilproof) cable 2m(Standard) φ6mm(*1) |
Weight |
Approx. 150g(Cable not included) |
Accessories |
Operation manual (1 copy)(Specify English or Japanese.)
Test report (1 copy) |
|