■Multiple process inputs: 4~20mA, 0~5V, 1~5V and 0~10V
■Power supply of sensor is built-in.(DC24V Capacity: 50mA)
■Models with analog outputs are multiple output type: 0~10V, -10~10V, 1~5V and 4~20mA.
■Full high-intensity LEDs.
■CE-certified.
■Alarm setting 2 points(Three relay output or Photo-coupler Output)
■Pattern select function included (Up to eight patterns)
■Peak hold functions
"sample hold", "Peak hold", "Bottom hold" and "peak-to-peak" functions included.
■Various functions
"Leading zero suppress", "Forced-zero" and "Reelay reset" functions included.
Specification
Input Method |
Single-end |
A/D Conversion Method |
ΔΣ conversion method |
Sampling Rate |
MAX. 250 times / sec. |
Display |
Main display:
Red/Green 7 segments LED display(Character height: Approx. 14.9mm)
Sub display:
White 7 segments LED display(Character height: Approx. 9mm) |
Polarity Display |
Displayed automatically for negative results. |
Display Range |
-19999~99999 |
Zero Display |
Leading zero suppress |
Outer Control |
4 out of the following 5 functions are assigned to the external control terminals.
* If the pattern select function is included, the remaining terminals available for other functions will be limited.
2 more functions (if 4 patterns used) or 1 more function (if 8 patterns used)
①Pattern select
②Hold
③Peak hold / Bottom hold / Peak to peak (Difference between the peak and the bottom)
④Forced-zero
⑤Relay reset |
Range of Use Temperature |
-5~50°C |
Range of Use Humidity |
35~85%RH(No condensation) |
Storage Temperature Range |
-10~70°C |
Storage Humidity Range |
60%RH or less |
Power |
AC100~240V±10% 50/60Hz |
Power Consumption |
AC100V: 12VA max.
AC240V: 15VA max. |
External Size |
96mm(W)×48mm(H)×99.7mm(D) |
Mass |
Approx. 250g |
Dielectric Strength |
Between Power terminal and Input terminal / External control terminals /Analog output AC2000V for 1 minute |
Between Power terminal and Comparative output AC1500V for 1 minute |
Between Input terminal and External control terminals/ Analog output / Comparative output AC1500V for 1 minute |
Between Case and Terminal AC2000V for 1 minute |
Insulation Resistance |
100MΩ min. at 500V DC between above terminals |
IP Rating |
IP66(Front) |
Case (Material / Color) |
Polycarbonate / Black UL94V-0 |
Overrange Display |
OVER or –OVER for any input signal outside the display range.
"OVER" or "-OVER" is displayed if input exceeds the measurement range by more than ±10%. |
Decimal Point |
Can be set at any desired place. |
Process signal input specifications
Measuring Range |
1~5V, ±5V, ±10V, 4~20mA, ±20mA |
Display |
Offset: -19999~99999 Full scale: -19999~99999 Resolution: ±19999 |
Input Impedance |
Approx. 1MΩ: (1~5V, ±5V, ±10V)
Approx. 10Ω: (4~20mA, ±20mA) |
Maximum Safe Input |
±100V: (1~5V, ±5V, ±10V)
±50mA: (4~20mA, ±20mA) |
Accuracy * |
±(0.1% of FS +1digit) (At the time of 23℃±5°C and 35~85%RH) |
|