- Taking the service box to the measurement site
- Activate device and connect sensor
- Feed sensor into sensor hole and start analysis at the touch of a button
- SAFE absorbs a gas sample and displays its concentration in vol.%
- The gas sample passes through the chromatographic column and the display of methane and ethane (if applicable) takes place
- The results display shows the clear results alongside the measured gas concentrations
- A results protocol is printed out and in addition, the measurement is saved in the memory
- Robust complete system in a service box
- Fully automatic sampling and analysis
- Reliable measurement result within five minutes
- Automatic valudation by the measurement system
- Documentation of the measurement with the built-in printer
- Data memory and infrared interface to transfer all measurement data to the PC
Thông số kỹ thuật
- Display : LCD graphic display 128 x 64 pixels, illuminable
- Power supply : Lead accumulator, integrated load system with 12V input
- Operating time : Depending on outside temperature, over 50 analyses
- Analysis range : Depending on the ethane concentration in natural gas from approx. 1,000 ppm to 100 vol.-% natural gas
- Operating temperature : - 10°C to + 45°C
- Documentation : built-in thermo printer and memory
- Dimensions : Width 35cm, Depth 30cm, Height 15cm
- Weight : 5,600 g approx