- First sensor: Extremely quick response on smallest hydrogen concentrations. Specialised for hydrogen with a resolution of 0,1 ppm H2
- Second sensor: to protect the first sensor and used for higher concentrations e.g. pinpointing in pinholes
- Integrated powerful pump for a high flow and underpressure
- Professional probes for effective operation in different situations
- Carpet probe TS14 for fixed surfaces
- Carbon bell probe for non fixed surfaces
- Pinhole probe for pinpointing in pinholes
- Air concentration probe V2 for pipes above ground or wall
Thông số kỹ thuật
- Display : LCD graphic display 128 x 64 pixels, illuminable
- Power supply : NiMH rechargeable battery pack
- Operating temperature : -10°C ... + 50°C
- Operating time : > 10 Stunden (without backlight)
- Charging Charging : cradle supplied by 12 Volt DC or 230 Volt AC, charging time approx. 5 hours
- High sensitive range :
+ measurement range: 0 … 1.000 ppm H2, resolution: 0,1 ppm
+ Response time: T90 < 5 seconds for H2 (hydrogen)
- Sensor for locating :
+ measurement range: 0 … 5 Vol.% H2 in N2, resolution: 0,01 %
+ Response time: T90 < 5 seconds for H2 (hydrogen)
- Pump : > 40 l/h, > 300 mbar
- Protection : IP 54
- Dimensions : 168 x 90 x 80 mm (without couplings)
- Weight : approx. 1.100 g